Your boiler has detected that water is not circulating correctly through the system, causing it to shut down for safety.
Book a Gas Safe engineer within 24–48 hours. Your boiler may be unsafe or could break down completely if left.
Technical description: Flow check failed
What causes this fault?
This fault occurs when the boiler's internal sensors detect that heated water isn't moving away from the heat exchanger quickly enough. The most common reasons are a seized or failing circulation pump, a build-up of sludge blocking the pipes, or simply air trapped within the system preventing flow.
This issue is more frequent in autumn when heating systems are first turned back on after being idle all summer, which can cause internal pump components to stick.
DIY fix possible
Check that the central heating pressure gauge is between 1 and 1.5 barEnsure all radiator valves are fully openCheck that the boiler isolation valves underneath the unit are switched to the open positionReset the boiler using the 'R' or Reset button