Low boiler pressure: how to repressurise your boiler

Low boiler pressure is one of the most common boiler problems — and one of the few you can safely fix yourself. If your pressure gauge reads below 1 bar, or your boiler has shut down showing a pressure fault code, this guide will walk you through topping it up.

ℹ️

What's the correct boiler pressure?

Cold system: 1.0–1.5 bar  ·  Hot system (running): 1.5–2.0 bar. Anything below 0.8 bar when cold is too low.

How to repressurise your boiler

1

Check the pressure gauge

Find the pressure gauge on your boiler — usually a circular dial or digital display on the front. If it reads below 1 bar with the heating off, it needs topping up.

2

Turn off and cool down

Switch the boiler off at the controls and wait at least 30 minutes for it to cool. Never repressurise a hot system.

3

Find the filling loop

Look underneath the boiler for the filling loop — a short, flexible silver or braided hose connecting two pipes. Some boilers have a built-in filling key or lever instead.

4

Open the filling valves slowly

Open both valves on the filling loop (usually a quarter-turn so the slot aligns with the pipe). You'll hear water entering the system. Open them slowly — the pressure rises quickly.

5

Watch and stop at 1.2–1.5 bar

Keep your eye on the pressure gauge. Close both valves as soon as the needle reaches 1.2–1.5 bar. Overfilling causes a different problem (pressure too high).

6

Restart and monitor

Turn the boiler back on. It may need a reset — hold the reset button for 3–5 seconds. Once running, check the pressure again when the system is hot: it should read 1.5–2 bar. If it drops again within a few days, there's a leak somewhere.

Fault codes for low pressure

E9 Worcester Bosch
F22 Vaillant
E1 / 108 Baxi
F1 / L1 Ideal
E1 Potterton
F22 Glow-worm
E9 Alpha
F9 Viessmann

When to call an engineer

  • Pressure drops again within days of topping up (indicates a leak)
  • You can't find the filling loop or filling key
  • The boiler still shows a fault code after topping up and resetting
  • Pressure is dropping very rapidly
  • You can see water leaking from the boiler or pipework

Pressure keeps dropping?

A Gas Safe engineer can find and fix the leak.

Find an engineer →