BoilerFaultCodes.com

Ideal Vogue Gen2 Fault Codes

System Natural GasLPG 15-32 kW 2016-present
GC Numbers: 41-431-1541-431-1641-431-17

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

All 19 fault codes

Code Severity Plain English
4.4 High Your boiler is struggling to keep a flame lit, which means the system has safely shut itself down to prevent a fault.
4.5 High Your boiler has overheated to a critical level and a safety component has permanently cut the power to prevent serious damage.
4.6 High Your boiler thinks it sees a flame before it has even started the ignition process, which is a safety conflict that prevents it from running.
4.7 High Your boiler has detected a problem with the internal sensor that measures the temperature of the water leaving the unit, preventing it from heating correctly.
4.8 Low Your boiler has lost communication with the sensor that monitors the outdoor temperature, meaning it might not heat your home as efficiently as usual.
4.9 High Your boiler has lost its ability to measure the temperature of the water coming back from your radiators, often resulting in the system shutting down for safety.
4.10 High Your boiler has stopped working because the fan that safely removes exhaust gases isn't running at the correct speed.
4.11 High Your boiler has detected that there is not enough water in the system to operate safely, causing it to shut down to prevent damage.
4.12 High Your boiler has stopped working because it cannot detect water moving through the system to keep it from overheating.
4.13 High Your boiler's internal computer parts are failing to talk to each other, meaning the system cannot receive the instructions it needs to start up.
4.14 Medium Your boiler is providing hot water to your taps correctly, but there is a communication or mechanical fault preventing it from heating your radiators.
4.15 Medium Your boiler is providing central heating as normal, but it has stopped producing hot water when you turn on your taps.
4.16 High Your boiler has lost power or the screen has stopped working, meaning you cannot see the status of your heating and hot water.
BLANK DISPLAY High Your boiler has no power or the control screen has failed, meaning the heating and hot water will not work until electricity is restored to the unit.
FAN FAULT High Your boiler has detected a problem with its internal fan and has shut down as a safety precaution, meaning you will not have any heating or hot water.
FLOW TEMPERATURE SETPOINT CANNOT BE INCREASED TO 80ºC Low Your boiler's maximum temperature has been restricted in its internal settings, preventing it from reaching the heat level requested by your thermostat.
PCB FAULT High Your boiler's main internal computer has developed a critical software or hardware failure and can no longer control the heating or hot water safely.
PCB REPLACED Low Your boiler has recently had its main circuit board replaced and simply needs to be rebooted to confirm the change.
SERVICE DUE Low Your boiler is working correctly, but it has been a year since its last official check-up and it is now requesting its annual safety service.

Protect yourself from future repair bills

Monthly cover means no unexpected bills when your boiler breaks down.

Top rated
OpenFix
Boiler & heating care plans
Get a quote →
Hometree
from £12.95/month
Get a quote →
HomeServe
from £8.00/month
Get a quote →

Affiliate links — we may earn a commission at no extra cost to you.