All 58 fault codes

Code Severity Plain English
0 Low Your boiler is currently waiting for a signal to provide heating or hot water and is operating normally in standby mode.
1 High Your boiler is currently stuck in a safety cycle where it is running the fan to clear gas or heat, but is not moving on to the ignition stage.
2 Low Your boiler is currently attempting to light the flame to heat your home or water, which is a normal part of its operation.
3 Low Your boiler is working correctly but is telling you that the room thermostat has been turned up to call for heat.
4 Low Your boiler is currently working as it should to heat up your tap water and is not experiencing an actual fault.
5 Low Your boiler has reached the required temperature and is taking a short, planned break to prevent overheating before it starts heating your home again.
6 Low Your boiler is working fine but is simply waiting because your thermostat is turned down or your heating schedule hasn't started yet.
7 Low Your boiler is continuing to run its internal water pump for longer than expected after you have finished using hot water.
8 Low Your boiler has temporarily paused because the water inside has reached its maximum set temperature and is waiting for it to cool down before restarting.
9 High Your boiler has paused operation because an external safety device or control, such as a thermostat or pump, has disconnected the circuit.
C0 Low Your boiler is working correctly and is simply waiting for a command from your thermostat to start heating.
C1 Low Your boiler is busy clearing out any leftover gases before it tries to ignite again.
C2 Low Your boiler is currently attempting to start up and light the flame to provide heating or hot water.
C4 Low Your boiler is simply notifying you that it is currently busy heating your tap water and there is no actual fault.
C7 Medium Your boiler is continuing to run its internal pump after you have finished using hot water, which is often caused by a stuck internal valve or a sensor error.
e0 High Your boiler has detected a problem with its internal temperature sensors, meaning it cannot accurately monitor the water temperature and has shut down as a safety precaution.
é0 High Your boiler has detected a problem with its internal temperature sensors, meaning it cannot accurately monitor the water temperature and has shut down as a safety precaution.
e1 High Your boiler is struggling to ignite or detect a flame, causing the system to stop as a safety precaution.
E01 High Your boiler has shut down because its internal temperature got too hot, likely due to a circulation problem or a blockage.
é1 High Your boiler has detected that the water inside is getting too hot too quickly, usually because there isn't enough water pressure or the water isn't moving through the pipes properly.
e2 High Your boiler is struggling to ignite or detect a flame at the beginning of its start-up process.
E02 High Your boiler has shut down because the water inside has become far too hot, which is often caused by a blockage or a pump that isn't moving water around the system properly.
é2 High Your boiler has detected that water is not circulating correctly, often because there is trapped air or the system pressure is too low.
e3 High Your boiler has detected an electrical connection issue or an internal fault in its main control computer, causing it to stop working for safety.
E03 High Your boiler has shut down because the internal gases have become too hot, which is a safety measure to prevent damage to the system.
e4 High Your boiler has tried to light several times but cannot establish a flame, meaning you will have no heating or hot water.
E04 High Your boiler is failing to light the gas burner properly and has locked itself out for safety after several unsuccessful tries.
e5 High Your boiler is failing to light the gas or keep the flame burning, leading to a safety lockout.
E05 High Your boiler was working but the flame has unexpectedly gone out, meaning the system has stopped providing heat for your safety.
e6 High Your boiler detects a flame when there shouldn't be one, which is a safety mechanism that prevents the unit from firing up.
E06 High Your boiler's internal computer has encountered a critical communication error and can no longer safely operate the heating system.
e7 High Your boiler is struggling to ignite or detect a flame correctly during its starting sequence and has paused for safety.
E07 High Your boiler has detected a problem with the sensor that monitors the temperature of the water leaving the unit, causing it to shut down to prevent overheating.
e8 High Your boiler has detected an issue with the air fan, preventing it from starting safely or clearing exhaust fumes correctly.
E08 High Your boiler has stopped working because it cannot correctly read the temperature of the water returning to the unit.
E09 High Your boiler’s main computer brain has encountered a serious internal error and has stopped working to protect the system.
E10 High Your boiler has stopped working because the water pressure inside the system has dropped too low to operate safely.
E11 High Your boiler's computer brain has encountered an internal error and can no longer control the heating system safely.
E12 High Your boiler's computer brain has developed a software or hardware glitch and can no longer communicate with the rest of the system.
E13 High Your boiler's internal computer has encountered a communication or hardware malfunction and cannot operate safely.
E14 High Your boiler's main internal computer has developed a communication fault or an electronic failure, preventing the system from operating safely.
E15 High Your boiler's internal computer brain has developed a communication fault and cannot operate properly.
E16 High Your boiler's internal computer brain has developed a communication fault and can no longer process instructions safely.
E17 High Your boiler's computer brain has encountered a communication error or internal failure and cannot safely operate.
E31 High Your boiler has detected a problem with the sensor that measures hot water temperature, which often means your hot water may be cold or inconsistent.
E32 Low Your boiler's external temperature sensor is sending an incorrect signal, which usually means the system cannot adjust its heating based on the weather outside.
E34 High Your boiler's fan is not spinning at the correct speed, which means it cannot safely clear waste gases or bring in fresh air to stay lit.
E35 High Your boiler's internal computer has detected a problem with how it manages the flame, causing it to shut down for safety.
E36 High Your boiler's main internal computer has developed a communication or electronic fault, causing the system to stop working for safety.
E37 High Your boiler's computer parts are having trouble talking to each other, which means the system cannot operate or provide heating and hot water.
E38 High Your boiler's main internal computer has lost touch with the front display screen, meaning they can no longer talk to each other to operate the heating.
E39 High Your boiler has shut down because a safety sensor has detected that it is getting too hot or that there is an issue with the gas supply pressure.
E40 High Your boiler's computer brain has encountered an internal software or hardware communication failure, causing the system to shut down for safety.
E41 High Your boiler's internal computer has encountered a critical communication error and cannot process commands to heat your home.
E42 High Your boiler's main internal computer has developed a communication fault or electronic failure, preventing it from managing the heating system.
e43 High Your boiler's computer memory has encountered a configuration error where internal settings have fallen outside of their safe operating ranges.
e44 High Your boiler's internal computer has detected an error in its configuration settings and needs a professional to reset internal parameters.
e45 High Your boiler's internal computer has suffered a software failure and can no longer process the settings needed to operate safely.

Remeha Avanta Plus is discontinued — time for a new one?

Parts for discontinued models can be hard to find and expensive. A new A-rated boiler could save you money on both repairs and energy bills.

UK's #1 online installer
Boxt
Fixed-price online quotes. Next-day installation.
Get a free quote →
Heatable
Instant online boiler quotes from £1,499.
Get a free quote →
iHeat
Fast installation. Price match guarantee.
Get a free quote →

Affiliate links — we may earn a commission at no extra cost to you.