Your boiler has lost connection to one of its internal temperature sensors, which means it cannot accurately monitor the heat for one of your heating zones.
This fault should be looked at by a Gas Safe engineer within the next week or two. It may get worse if left.
Technical description: Control mode without room influence - Heating circuit M2 room temperature sensor lead break
What causes this fault?
This fault occurs when the boiler loses signal from the temperature sensor responsible for monitoring a specific heating zone. It is typically caused by a loose connection plug, damaged wiring, or a failed sensor component that can no longer send electrical data to the main control board.
Engineer required
This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.