BoilerFaultCodes.com
dE Medium Warning

Your boiler has lost connection to one of its internal temperature sensors, which means it cannot accurately monitor the heat for one of your heating zones.

Book a service

This fault should be looked at by a Gas Safe engineer within the next week or two. It may get worse if left.

Technical description: Control mode without room influence - Heating circuit M2 room temperature sensor lead break

What causes this fault?

This fault occurs when the boiler loses signal from the temperature sensor responsible for monitoring a specific heating zone. It is typically caused by a loose connection plug, damaged wiring, or a failed sensor component that can no longer send electrical data to the main control board.

Typical repair cost £90-180 (including labour)

Engineer required

This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer

Search the official register for a qualified engineer in your area.

Gas Safe Register →

Protect yourself from future repair bills

A boiler cover plan would cover faults like dE — no call-out fees, no surprises.

Top rated
OpenFix
Boiler & heating care plans
Get a quote →
Hometree
from £12.95/month
Get a quote →
HomeServe
from £8.00/month
Get a quote →

Affiliate links — we may earn a commission at no extra cost to you.

Viessmann Vitodens 333 is discontinued — time for a new one?

Parts for discontinued models can be hard to find and expensive. A new A-rated boiler could save you money on both repairs and energy bills.

UK's #1 online installer
Boxt
Fixed-price online quotes. Next-day installation.
Get a free quote →
Heatable
Instant online boiler quotes from £1,499.
Get a free quote →
iHeat
Fast installation. Price match guarantee.
Get a free quote →

Affiliate links — we may earn a commission at no extra cost to you.

Related fault codes