Common problems guide

The most common Ariston Clas ONE System problems

The faults most likely to send a Ariston Clas ONE System into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

16 documented codes
6 most common
5 DIY-safe checks
1 engineer needed

The 6 most common faults

01
106 High DIY-safe

Your boiler has stopped working because the water returning from your radiators is significantly hotter than the water leaving the boiler, suggesting the water isn't flowing correctly.

What to try first

Ensure all radiator valves (TRVs) are turned to the highest settingCheck that at least one radiator or bypass valve is fully openBleed all radiators to remove trapped air locks

Est. cost
£120-350
Parts
Circulation Pump, Return Temperature Sensor (NTC), Main Heat Exchanger (if blocked)
Full guide for 106
02
107 High DIY-safe

Your boiler has stopped working because the water returning from your radiators is significantly hotter than the water being sent out, suggesting a blockage or a pump problem is preventing proper circulation.

What to try first

Check that all radiator valves are fully openEnsure the central heating system pressure is between 1 and 1.5 bar on the gaugeGently bleed your radiators to remove any trapped airRestart the boiler using the Reset button

Est. cost
£120-£350
Parts
Circulation Pump, Main Heat Exchanger (cleaning or replacement), Flow/Return Thermistors
Full guide for 107
03
108 High DIY-safe

Your boiler has lost water pressure and has shut down to prevent damage, meaning it simply needs to be refilled to the correct level.

What to try first

Locate the filling loop (usually blue handles or a small plastic key) underneath the boiler.Slowly open the valves until you hear water entering the system.Watch the pressure gauge and close the valves tightly once it reaches 1.5 bar.The error code should clear automatically; if not, press the 'Reset' button.

Est. cost
£0-120
Parts
Filling loop valve, Expansion vessel, Auto air vent
Full guide for 108
04
501 High DIY-safe

Your boiler has tried to light several times but has failed to create a flame, meaning you currently have no heating or hot water.

What to try first

Check if your home gas supply is active by testing another gas appliance like a hob.Verify that your gas prepaid meter (if applicable) has enough credit.If it is freezing outside, check that the white plastic condensate waste pipe is not frozen.Hold the 'Reset' button for five seconds to see if the boiler restarts.

Est. cost
£100-350
Parts
Ignition Electrode, Gas Valve, Spark Generator
Full guide for 501
05
109 Emergency DIY-safe

Your boiler has too much water pressure inside the system, causing it to shut down for safety.

What to try first

Check that the filling loop valves under the boiler are tightly closed.Bleed water from a radiator using a bleed key until the pressure gauge on the boiler falls back between 1 and 1.5 bar.Restart the boiler once the pressure is stabilised.

Est. cost
£80-200
Parts
Filling loop valve, Expansion vessel, Pressure relief valve (PRV)
Full guide for 109
06
116 High Engineer

Your boiler has detected that the safety sensor for an underfloor heating circuit has tripped to prevent the floor from overheating.

Est. cost
£90-180
Parts
Floor thermostat, Overheat limit thermostat, Wiring harness
Full guide for 116

on the Ariston Clas ONE System

Circulation PumpReturn Temperature Sensor (NTC)Main Heat Exchanger (if blocked)Main Heat Exchanger (cleaning or replacement)Flow/Return ThermistorsFilling loop valve

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Ariston shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill