Ariston Egis HE 30 Fault codes & diagnostics

31 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Natural Gas
GC Number 47-116-72
Download the Ariston Egis HE 30 manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 26 High 3 Medium 1 Low

All 31 documented codes

Tap any card for details

1 01

Your boiler has detected that it is getting too hot and has automatically shut down to prevent damage to its internal systems.

High Engineer only £120-250

Parts commonly replaced

  • Pump
  • Diverter valve
  • Primary heat exchanger
  • Temperature sensor

Related codes

1 03

Your boiler has detected that there is not enough water flowing through the system to keep it running safely.

High DIY-safe

What to check first

  1. Locate the filling loop valves beneath your boiler.
  2. Open the valves gently to top up the system pressure until the gauge reads between 1.0 and 1.5 bar.
  3. Close both valves tightly and press the reset button on your boiler.

Parts commonly replaced

  • Pressure relief valve
  • Pressure sensor
  • Circulating pump

Related codes

1 04

Your boiler has stopped working because the water isn't flowing properly through the system.

High Engineer only £150-350

Parts commonly replaced

  • Circulation Pump
  • Automatic Air Vent
  • Pressure Switch

Related codes

1 05

Your boiler has detected that water is not flowing properly through the system, which can cause it to overheat and shut down to protect itself.

High DIY-safe £100-£250

What to check first

  1. Check that your boiler pressure gauge is between 1 and 1.5 bar
  2. Top up the system pressure using the filling loop if it is too low
  3. Bleed your radiators to remove any trapped air that might be blocking water flow
  4. Ensure all radiator valves are fully open

Parts commonly replaced

  • Circulating pump
  • Automatic bypass valve
  • Plate heat exchanger

Related codes

1 06

Your boiler has failed to ignite the burner properly and has locked out for safety.

High Engineer only £150-300

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

1 07

Your boiler has shut down because the water pressure inside the system is too low to operate safely.

High DIY-safe

What to check first

  1. Locate the filling loop valves underneath your boiler.
  2. Open the valves gently to allow water to enter the system until the pressure gauge reads between 1.0 and 1.5 bar.
  3. Close both valves firmly and press the reset button on your boiler.

Parts commonly replaced

  • Pressure relief valve
  • Pressure sensor
  • Expansion vessel

Related codes

1 08

Your boiler has detected that the water pressure inside the system is too low to run safely, and it needs you to top it up using the filling loop.

High DIY-safe

What to check first

  1. Locate the filling loop (usually flexible hoses with small valves underneath the boiler).
  2. Open the valves gently to allow mains water into the heating system.
  3. Watch the pressure gauge on the front of the boiler until the needle reaches between 1.0 and 1.5 bar, then firmly close the valves.

Parts commonly replaced

  • Filling loop valve
  • Pressure relief valve
  • Pressure sensor

Related codes

1 09

Your boiler has too much water inside its system, causing it to shut down to prevent damage from high pressure.

High DIY-safe £0-120

What to check first

  1. Check that the filling loop valves are fully closed and not letting in water
  2. Bleed water from a radiator using a bleed key to reduce the system pressure
  3. Monitor the pressure gauge until it returns to between 1 and 1.5 bar
  4. Restart the boiler once the pressure is within the normal operating range

Parts commonly replaced

  • Filling loop valve
  • Pressure relief valve (PRV)
  • Expansion vessel

Related codes

1 10

Your boiler has stopped working because it can no longer accurately read the temperature of the water circulating through your radiators.

High Engineer only £120-180

Parts commonly replaced

  • Central Heating NTC Flow Sensor

Related codes

1 12

Your boiler has lost the ability to read the temperature of the water returning to it from your radiators, so it has shut down to prevent potential damage.

High Engineer only £120-200

Parts commonly replaced

  • Central Heating Return NTC Thermistor
  • Wiring harness

Related codes

Showing 11–20 of 31
1 14

Your boiler is having trouble communicating with the outdoor weather sensor, which helps it decide how hard to work based on the outside temperature.

Low Engineer only £90-180

Parts commonly replaced

  • External temperature sensor
  • Wiring loom

Related codes

1 16

Your boiler has detected that the external temperature safety switch—typically used for underfloor heating—is triggered or disconnected, preventing the system from running safely.

Medium Engineer only £100-200

Parts commonly replaced

  • Floor thermostat
  • Wiring link
1 P1

Your boiler has failed to ignite properly and stopped working because it did not detect a flame after several attempts.

High DIY-safe £90-200

What to check first

  1. Check if your gas supply is working by testing another gas appliance like a hob.
  2. Locate the reset button on your Ariston boiler and hold it down for 5 seconds to restart the system.
  3. Check your condensate pipe outside to ensure it isn't frozen or blocked, which can prevent the boiler from firing.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

1 P2

Your boiler has temporarily stopped because it is not detecting enough water flowing through the system.

High DIY-safe £90-250

What to check first

  1. Check your boiler pressure gauge to ensure it is sitting between 1 and 1.5 bar.
  2. If the pressure is too low, use the filling loop to top up the system.
  3. Reset the boiler once the correct pressure is restored.

Parts commonly replaced

  • Circulating pump
  • Automatic air vent
  • Pressure sensor

Related codes

1 P3

Your boiler is failing to ignite properly and has stopped working to keep you safe.

High Engineer only £100-£250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

2 05

Your boiler's optional solar water heating sensor is disconnected or faulty, which may prevent your hot water from heating up correctly.

Medium Engineer only £120-200

Parts commonly replaced

  • Solar DHW probe
  • Wiring harness
3 01

Your boiler's internal computer memory has encountered a reading or writing error, preventing the system from functioning correctly.

High Engineer only £250-£450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Display PCB Board

Related codes

3 02

Your boiler's internal computer is struggling to talk to its control parts, preventing it from functioning correctly.

High Engineer only £150-300

Parts commonly replaced

  • Main PCB
  • Wiring harness
  • Display interface unit

Related codes

3 03

Your boiler’s main internal control board has developed a technical fault, preventing the system from starting up or operating safely.

High Engineer only £250-£450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • Wiring Harness

Related codes

3 04

Your boiler has been manually reset more than five times in fifteen minutes and has temporarily locked itself for safety.

Medium DIY-safe £0-120

What to check first

  1. Turn off the power supply to the boiler at the fused spur switch.
  2. Wait for at least 15 minutes without touching any buttons to allow the internal timer to reset.
  3. Turn the power back on and see if the boiler resumes normal operation.

Parts commonly replaced

  • No parts usually required
  • Printed Circuit Board (PCB) if the error persists

Related codes

Showing 21–30 of 31
3 05

Your boiler's internal computer is experiencing a communication error, meaning it has lost track of its own operational state and cannot safely run.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB
  • Wiring harness

Related codes

3 06

The internal computer that controls your boiler is experiencing a communication error and cannot operate the system safely.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB

Related codes

3 07

Your boiler's internal computer is experiencing a communication error and has shut down to prevent potential hardware damage.

High Engineer only £200-400

Parts commonly replaced

  • Main Printed Circuit Board (PCB)

Related codes

5 01

Your boiler has tried to start up, but it cannot detect a flame to keep it running safely.

High DIY-safe £150-350

What to check first

  1. Check if your gas supply is working by testing another gas appliance like a cooker.
  2. Ensure your gas prepayment meter has credit if you use one.
  3. Locate the reset button on your Ariston boiler and hold it down for 5-10 seconds to attempt a restart.

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

5 02

Your boiler’s internal safety sensor thinks the burner is still lit even though it should be turned off, which prevents the system from starting safely.

Emergency Engineer only £150-300

Parts commonly replaced

  • Gas valve
  • Main PCB
  • Flame rectification probe

Related codes

5 04

Your boiler is struggling to keep the flame stable, which is preventing it from heating your water or home properly.

High Engineer only £120-250

Parts commonly replaced

  • Gas valve
  • Burner seal
  • Electrode assembly

Related codes

5 P1

Your boiler tried to start up but couldn't create a flame on its first attempt, meaning you likely have no heating or hot water right now.

High DIY-safe £100-280

What to check first

  1. Check that your gas emergency control valve is in the 'on' position
  2. If you have a prepaid gas meter, ensure you have sufficient credit
  3. Press the Reset button on the control panel to allow the boiler to try again

Parts commonly replaced

  • Ignition Electrode
  • Flame Sensing Electrode
  • Gas Valve

Related codes

5 P2

Your boiler has tried to start twice but has failed to successfully light its internal flame.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ignition transformer

Related codes

5 P3

Your boiler has stopped during operation because the main burner flame has unexpectedly gone out.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Flame rectification probe
  • Gas valve

Related codes

6 10

Your boiler has shut down because the internal water temperature has become too hot, likely due to a blockage or a pump failure.

High DIY-safe £120-£350

What to check first

  1. Check that your radiator valves are open to allow water to circulate.
  2. Ensure the system pressure is between 1 and 1.5 bar on the gauge.
  3. Restart the boiler using the Reset button.

Parts commonly replaced

  • Circulation Pump
  • Main Heat Exchanger
  • Overheat Thermostat

Related codes

Showing 31–31 of 31
6 12

Your boiler has detected that the internal fan responsible for safely pushing exhaust gases outside is not spinning fast enough.

High Engineer only £150-300

Parts commonly replaced

  • Flue gas fan
  • Air pressure switch
  • Printed Circuit Board (PCB)

Related codes