FILL (flashing) on Atag E Range

Your boiler has lost water pressure and needs to be topped up to work at full capacity correctly.

Book a service

This fault should be looked at by a Gas Safe engineer within the next week or two. It may get worse if left.

Technical description

Water pressure is to low (<1,0 bar), flashing FILL will be altered with indication of water pressure, boiler power of 50% is possible. The installation needs to be topped up.

DIY fix possible

Locate the external filling loop, usually a silver braided hose with one or two valves located underneath the boiler.Slowly open the valve(s) to allow mains water into the system until the pressure gauge reads between 1.0 and 1.5 bar.Close the valve(s) tightly and check for any leaks around the connection points.