Atag 117 Fault Code
The Atag 117 fault code means: your boiler has detected that there is too much water pressure in the system or the pump is forcing water through too quickly.. It appears on 8 Atag models in our database.
Technical description: Pressure too high (>3 bar) or pump pressure increase too high
DIY fix possible
Check that the internal or external filling loop valves are tightly closed.Locate a radiator bleed valve and use a key to release water into a cloth until the pressure gauge returns to 1.5 bar.Restart the boiler once the pressure is back in the green zone.