Atag FILL (continuous) Fault Code
Also written as FILLCONTINUOUS — same fault.
The Atag FILL (continuous) fault code means: your boiler has stopped working because the water pressure inside the system has dropped too low and needs to be topped up.. It appears on 2 Atag models in our database.
Technical description: Water pressure is to low (<0,7 bar), FILL indication remains continuously visible, the boiler is taken out of operation. The installation needs to be topped up.
DIY fix possible
Locate the external filling loop, which is a small silver braided hose connecting two pipes near your boiler.Open the valves at both ends of the hose to allow mains water to enter the system until the pressure gauge reads between 1.0 and 1.5 bar.Close both valves tightly to stop the flow of water and ensure the pressure gauge stays steady.