Atag iR32 Fault codes & diagnostics

15 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Regular Natural Gas 2015-present
GC Number 41-310-38
Download the Atag iR32 manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 9 High 1 Medium 4 Low

All 15 documented codes

Tap any card for details

10

Your boiler has lost communication with the weather sensor outside your home and is now running on its default safety settings.

Low Engineer only £100-200

Parts commonly replaced

  • Outside temperature sensor
  • Wiring harness
20

Your boiler is struggling to detect the flow of water through its system, which means it cannot safely heat your home or provide hot water.

High Engineer only £150-250

Parts commonly replaced

  • Flow sensor
  • Wiring harness
40

Your boiler is struggling to accurately read the temperature of the water returning to it, which prevents it from heating your home reliably.

High Engineer only £150-250

Parts commonly replaced

  • Return NTC sensor
  • Wiring harness
50

Your boiler is having trouble detecting the temperature of the water coming from your taps, which means it cannot heat your hot water properly.

High Engineer only £150-250

Parts commonly replaced

  • Domestic Hot Water (DHW) Sensor
  • NTC Sensor wiring harness
61

Your boiler is having trouble communicating internally with its control components, meaning it cannot currently receive instructions to heat your home.

High Engineer only £120-450

Parts commonly replaced

  • Wiring harness
  • Main PCB
  • Internal bus controller
105

Your boiler is currently running a brief internal safety check to clear out trapped air after the electricity was recently interrupted or switched back on.

Low DIY-safe

What to check first

  1. Wait for approximately 7 minutes for the automatic venting program to finish running.
  2. Do not turn off or reset the boiler while this cycle is in progress.
  3. Once the timer completes, the boiler should return to normal operation automatically.
110

Your boiler has detected that it is getting dangerously hot and has shut itself down to prevent damage.

Emergency Engineer only £150-350

Parts commonly replaced

  • Circulating pump
  • Heat exchanger
  • NTC temperature sensor
  • Diverter valve
111

Your boiler has switched itself off because it has become too hot internally, likely due to a lack of water flow or a blockage.

High DIY-safe £120-450

What to check first

  1. Check that your central heating pressure is between 1.0 and 1.5 bar on the pressure gauge.
  2. Ensure all radiator valves and internal stop taps are fully open to allow water to flow.
  3. Try resetting the boiler by pressing the 'Reset' button on the control panel.

Parts commonly replaced

  • Circulation Pump
  • Main Heat Exchanger
  • Overheat Thermostat

Related codes

119

Your boiler has lost its internal electrical connection signal, which is usually caused by low water pressure or a loose wiring link inside the unit.

High DIY-safe £80-160

What to check first

  1. Check the pressure gauge on the front of the boiler or via the display.
  2. If the pressure is below 1.0 bar, use the filling loop to top it up to 1.5 bar.
  3. Press the 'Reset' button (the one with the circular arrow) to clear the fault.

Parts commonly replaced

  • Water pressure switch
  • Wiring harness connector
  • External controls link

Related codes

129

Your boiler's internal fan is failing to start, which means the system cannot safely clear exhaust fumes and has shut down as a precaution.

High Engineer only £250-450

Parts commonly replaced

  • Extraction Fan
  • Internal Wiring Harness
  • Printed Circuit Board (PCB)

Related codes

133

Your boiler has tried to light several times but cannot establish a flame, meaning your heating and hot water will not work.

High DIY-safe £100-350

What to check first

  1. Check if other gas appliances in your home, like a hob, are working to confirm gas supply.
  2. Ensure your gas meter has credit if you use a prepay meter.
  3. Check that the condensate pipe (the plastic pipe leading outside) isn't frozen if the weather is very cold.
  4. Press the Reset button once to see if the boiler restarts.

Parts commonly replaced

  • Ignition Electrode
  • Gas Valve
  • Condensate Trap
  • Spark Cable

Related codes

151

Your boiler's internal fan, which is responsible for safely venting fumes, is failing to spin at the correct speed, causing the system to stop working for safety reasons.

High Engineer only £200-350

Parts commonly replaced

  • Fan assembly
  • Control PCB

Related codes

154

Your boiler has detected an abnormal temperature difference between the water leaving it and the water returning, which usually indicates a circulation problem inside the system.

Medium Engineer only £150-350

Parts commonly replaced

  • Central heating pump
  • Flow sensor
  • NTC thermistor

Related codes

180

This is not an error code, but merely a notification confirming that the boiler's manual testing mode has finished successfully.

Low DIY-safe

What to check first

  1. No action is required.
  2. Wait a few seconds for the display to return to the normal operating screen.
181

This code is not an error; it simply confirms that your boiler has finished its setup or testing mode and is returning to normal operation.

Low DIY-safe

What to check first

  1. No action is required
  2. Wait for the boiler to return to its normal display
  3. Ensure the boiler is heating your water as expected

Avoid the next call-out bill