Common problems guide

The most common Baxi 800 System 2 problems

The faults most likely to send a Baxi 800 System 2 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

75 documented codes
6 most common
6 DIY-safe checks
0 engineer needed

The 6 most common faults

01
A.02.06 High DIY-safe

Your boiler has detected that there is not enough water in the central heating system to operate safely.

What to try first

Locate the filling loop (the silver braided hose) underneath the boiler.Slowly open the blue or black taps on the filling loop until you hear water flowing.Monitor the pressure gauge until it reaches between 1.0 and 1.5 bar, then close the taps fully.

Est. cost
£0-120
Parts
Filling loop, Expansion vessel, Pressure relief valve
Full guide for A.02.06
02
E.01.04 High DIY-safe

Your boiler is repeatedly struggling to keep the flame lit while it is running, causing it to shut down for safety after multiple failures.

What to try first

Check that your gas pre-payment meter has creditEnsure other gas appliances in your home, like a hob, are working correctlyReset the boiler by pressing the 'R' or 'Reset' button

Est. cost
£120-350
Parts
Flame sensing electrode, Gas valve, Ignition lead
Full guide for E.01.04
03
E.01.12 High DIY-safe

Your boiler has sensed that the water returning from your radiators is hotter than the water leaving the boiler, which usually means there is a circulation problem or a sensor fault.

What to try first

Ensure all radiator valves (TRVs) are fully openCheck that the boiler pressure is between 1.0 and 1.5 barPress the Reset button for five seconds

Est. cost
£90-220
Parts
Return temperature sensor (NTC thermistor), Flow temperature sensor, Central heating pump
Full guide for E.01.12
04
E.01.17 High DIY-safe

Your boiler has detected that water is not moving through the system properly, which has caused it to shut down to prevent overheating.

What to try first

Check the pressure gauge and top it up to 1.5 bar using the filling loop if it is too lowEnsure all radiator valves are fully openCheck for any visible leaks around your pipeworkRestart the boiler using the reset button

Est. cost
£100-£350
Parts
Circulation Pump, Water Pressure Sensor, Main Heat Exchanger (if blocked)
Full guide for E.01.17
05
E.04.03 High DIY-safe

Your boiler has shut down because it thinks it is getting too hot or it has detected a technical fault with its internal temperature sensor.

What to try first

Check that all radiator valves are fully openEnsure the boiler pressure is between 1 and 1.5 bar on the gaugeTurn the boiler off and back on again to attempt a reset

Est. cost
£90-180
Parts
Temperature Flow Sensor (NTC), Circulation Pump, Main Heat Exchanger cleaning
Full guide for E.04.03
06
E.04.08 High DIY-safe

Your boiler has shut down because the water inside has become far too hot, likely due to a circulation problem.

What to try first

Check that your radiator valves are fully openEnsure there is enough water pressure in the system (usually between 1.0 and 1.5 bar on the gauge)Try resetting the boiler by turning the selector knob to 'R' for five seconds

Est. cost
£120-£350
Parts
Circulation Pump, Overheat Thermostat, Main Heat Exchanger (Cleaning/Flushing)
Full guide for E.04.08

on the Baxi 800 System 2

Filling loopExpansion vesselPressure relief valveFlame sensing electrodeGas valveIgnition lead

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Baxi shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 75-code list for the Baxi 800 System 2