Common problems guide

The most common Baxi Solo 3 PF problems

The faults most likely to send a Baxi Solo 3 PF into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
6 documented codes
6 most common
1 DIY-safe checks
5 engineer needed

The 6 most common faults

01
E24 High Engineer

Your boiler has detected an issue with the valve that regulates the gas flow, meaning it cannot safely ignite or maintain a flame to heat your home.

Est. cost
£180-300
Parts
Gas Valve, Wiring Harness, PCB
Full guide for E24
02
E03 High Engineer

Your boiler has detected that it is getting too hot and has automatically switched itself off to prevent any damage or safety issues.

Est. cost
£120-250
Parts
Overheat Thermostat, Pump, PCB
Full guide for E03
03
E26 High Engineer

Your boiler has detected that the internal exhaust system is not working correctly, so it has safely shut down to prevent unsafe gases from building up.

Est. cost
£150-300
Parts
Fan assembly, Air pressure switch, Wiring harness
Full guide for E26
04
Overheat Neon High Engineer

Your boiler has switched itself off because it has detected that it is getting too hot, likely due to a circulation issue.

Est. cost
£120-250
Parts
Overheat thermostat, Pump, PCB
Full guide for Overheat Neon
05
E01 Emergency Engineer

Your boiler has failed to ignite because the internal flame sensor is not detecting a steady burn.

Est. cost
£120-250
Parts
Ignition electrode, Flame rectification probe, Gas valve
Full guide for E01
06
Lockout Medium DIY-safe

Your boiler has automatically turned itself off because it became too hot, acting as a safety measure to prevent damage.

What to try first

Turn the boiler control knob to the OFF position.Wait for at least 10 seconds to allow the internal sensors to reset.Turn the control knob back to the ON position and observe if the boiler fires up normally.

Est. cost
£100-250
Parts
Overheat thermostat, Pump, PCB
Full guide for Lockout

on the Baxi Solo 3 PF

Gas ValveWiring HarnessPCBOverheat ThermostatPumpFan assembly

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Baxi shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 6-code list for the Baxi Solo 3 PF