2 flashes red High

Baxi 2 flashes red Fault Code

Also written as 2FLASHESRED — same fault.

The Baxi 2 flashes red fault code means: your boiler has shut down because it has detected it is getting too hot, likely due to a lack of water circulation or a blocked flue.. It appears on 4 Baxi models in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: High temperature protection: Over-temperature thermostat on heat exchanger activated, No water flow through heat exchanger, Over-temperature thermostat fault or bad connection (open circuit), PCB over-temperature condition, Flue fault resulting in recirculation or activation of air pressure switch (if fitted)
Typical repair cost £120-350 (including labour)

DIY fix possible

Check that all radiator valves are fully open (at least two or three)Check that the external system pump is running if accessibleTurn the selector knob to the 'Reset' position for five seconds and release

Find a Gas Safe engineer

Search the official register for a qualified engineer in your area.

Gas Safe Register →

Avoid the next call-out bill

A cover plan would handle faults like 2 flashes red: no call-out fees, no surprise bills.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

Baxi models that show the 2 flashes red fault code

Click a model for the full fault code list and model-specific repair notes.

Source

Baxi 2 flashes red fault code information on this page is sourced and cross-checked against the official Baxi service / installation manuals for each affected model.

Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 7 July 2026