1 Emergency 16 High 1 Medium

All 18 documented codes

Tap any card for details

20

Your boiler has stopped working because it cannot accurately measure the temperature of the water being circulated to your radiators.

High Engineer only £120-220

Parts commonly replaced

  • Central Heating NTC sensor
  • Wiring harness

Related codes

28

Your boiler has detected a problem with a temperature sensor inside the flue system, which stops the unit from operating to ensure it remains safe.

High Engineer only £120-220

Parts commonly replaced

  • Flue NTC Sensor
  • Wiring harness
  • PCB

Related codes

40

Your boiler is struggling because a sensor that monitors the temperature of the water returning to the system is failing, which prevents it from heating your home correctly.

High Engineer only £120-220

Parts commonly replaced

  • Return NTC thermistor sensor
  • Wiring harness

Related codes

109

Your boiler has detected that water is not flowing through the system correctly, which is preventing it from heating your home safely.

High Engineer only £150-300

Parts commonly replaced

  • Central heating pump
  • System filter
  • Diverter valve

Related codes

110

Your boiler has switched itself off because it has reached too high a temperature, likely due to trapped air or a blockage stopping water from circulating.

High DIY-safe £100-250

What to check first

  1. Turn off the boiler and allow it to cool down completely.
  2. Use a radiator key to bleed all radiators to remove any trapped air.
  3. Check the boiler pressure gauge and top it up to 1.5 bar if it has dropped.
  4. Turn the boiler back on and press the 'Reset' button.

Parts commonly replaced

  • Overheat Thermostat
  • Circulating Pump
  • NTC Temperature Sensor
111

Your boiler has automatically shut down because it has detected that its internal water temperature has become dangerously high.

High Engineer only £120-250

Parts commonly replaced

  • NTC Temperature Sensor
  • Pump
  • Heat Exchanger

Related codes

117

Your boiler has too much water in the system, which puts extra stress on the internal parts and may cause it to shut down for safety.

Medium DIY-safe £80-160

What to check first

  1. Check that the filling loop valves are fully closed
  2. Switch off the boiler and allow the system to cool
  3. Bleed water from a radiator using a bleed key to reduce pressure
  4. Monitor the pressure gauge until it returns to between 1.0 and 1.5 bar

Parts commonly replaced

  • Filling loop valve
  • Pressure Relief Valve (PRV)
  • Expansion vessel

Related codes

118

Your boiler has detected that there is not enough water in the system to operate safely, causing it to shut down temporarily.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop (usually a silver flexible hose) underneath your boiler.
  2. Slowly open the one or two taps/valves on the filling loop until you hear water entering the system.
  3. Watch the pressure gauge until it reaches between 1.0 and 1.5 bar, then close the taps fully.

Parts commonly replaced

  • Filling loop valves
  • Expansion vessel
  • Pressure sensor

Related codes

125

Your boiler has detected that water isn't moving through the system properly, which is causing it to overheat and shut down for safety.

High DIY-safe £150-£350

What to check first

  1. Check that your system pressure is between 1 and 1.5 bar on the pressure gauge
  2. Ensure all radiator valves and isolation valves under the boiler are fully open
  3. Bleed your radiators to remove any trapped air pockets

Parts commonly replaced

  • Circulating Pump
  • Pump Lead
  • Main Heat Exchanger

Related codes

128

Your boiler started to heat up but the flame went out unexpectedly while it was running.

High DIY-safe £100-£350

What to check first

  1. Check that your gas pre-pay meter has credit
  2. Ensure other gas appliances in your home are working to confirm gas supply
  3. Press the 'Reset' button for five seconds

Parts commonly replaced

  • Flame sensing electrode
  • Ignition lead
  • Gas valve

Related codes

130

Your boiler has detected that the temperature of the gases leaving your flue is too high, so it has shut itself down to prevent any damage.

High Engineer only £150-250

Parts commonly replaced

  • Flue NTC sensor
  • Wiring harness
  • PCB

Related codes

133

Your boiler has tried to ignite but failed to stay alight, which is often caused by a lack of gas supply or a blocked condensation pipe.

High DIY-safe £100-£350

What to check first

  1. Check that your gas supply is turned on and you have credit on your meter.
  2. During freezing weather, check if your external white plastic condensate pipe is frozen and thaw it with warm water.
  3. Press the Reset button for five seconds.

Parts commonly replaced

  • Gas Valve
  • Ignition Electrode
  • Printed Circuit Board (PCB)
151

Your boiler has failed to light the flame needed to heat your water and home, and has safely shut down to prevent gas from building up.

High Engineer only £120-250

Parts commonly replaced

  • Ignition lead
  • Ignition electrode
  • Gas valve
  • PCB

Related codes

160

Your boiler's fan is not spinning at the correct speed, which prevents the system from safely clearing exhaust fumes and starting the ignition process.

High Engineer only £250-£450

Parts commonly replaced

  • Fan assembly
  • Printed Circuit Board (PCB)
  • Wiring harness
162

Your boiler has detected an issue with how it clears exhaust gases or brings in fresh air, preventing it from firing up for safety.

High Engineer only £120-£250

Parts commonly replaced

  • Air Pressure Switch
  • Venturi tube
  • Fan
321

Your boiler is struggling to accurately measure the temperature of the water being heated for your taps and shower, so it has stopped producing hot water to prevent damage.

High Engineer only £120-220

Parts commonly replaced

  • Domestic Hot Water NTC Sensor

Related codes

384

Your boiler has detected a flame signal when it should be turned off, so it has locked itself out to prevent a potential safety issue.

Emergency Engineer only £150-300

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Gas Valve
  • Flame Rectification Probe
E118

Your boiler has stopped working because the amount of water inside the system has dropped too low.

High DIY-safe £80-150

What to check first

  1. Locate the filling loop, which is a flexible silver hose connected to two valves under the boiler.
  2. Open the valves slowly to allow water into the system until the pressure gauge on the front reads between 1.0 and 1.5 bar.
  3. Close the valves firmly and check to ensure the boiler restarts.

Parts commonly replaced

  • Pressure relief valve
  • Expansion vessel
  • Pressure sensor

16 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.

01 Diagnostic Your boiler has detected that the water inside the heating system has become too hot and is shutting down to prevent damage. 02 Diagnostic Your boiler has lost communication with the weather sensor installed outside your home, meaning it cannot automatically adjust its temperature based on outdoor conditions. 03 Diagnostic Your boiler is struggling to accurately measure the temperature of the hot water it is attempting to provide. 04 Diagnostic Your boiler is having trouble sensing the temperature of your hot water, which prevents it from heating water properly for your taps. 05 Diagnostic Your boiler has detected that the water pressure inside the heating system is too low to operate safely. 06 Diagnostic Your boiler has detected that the water returning from your radiators is not at the expected temperature, causing it to stop heating to prevent internal damage. 07 Diagnostic Your boiler has detected that the flue gases are getting too hot, so it has safely shut itself down to prevent overheating. 10 Diagnostic Your boiler is struggling to accurately measure or circulate the hot water needed for your radiators. 12 Diagnostic Your boiler is failing to detect a flame, so it has safely shut itself down to prevent a gas build-up. 13 Diagnostic This code is simply an advisory reminder that your boiler has reached a pre-programmed number of operating hours and is due for its regular annual service. 14 Diagnostic Your boiler has detected a temperature issue in the central heating flow sensor, meaning it cannot accurately tell if your radiators are heating up properly. 15 Status Your boiler is signalling an issue with how it manages its secondary heating zone, which may prevent your home from warming up as expected. 16 Status Your boiler is struggling to correctly detect that you have turned on a hot water tap, meaning it isn't heating the water as it should. 17 Status Your boiler is currently running a background self-checking process or is in a temporary state of transition, so it should resolve itself automatically without any action on your part. 18 Status Your boiler is currently set to a special mode intended for systems connected to solar panels rather than standard household heating. 19 Diagnostic Your boiler has detected an internal communication error between its main control boards, which prevents it from operating correctly.

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.