Common problems guide

The most common Chaffoteaux 80/100 problems

The faults most likely to send a Chaffoteaux 80/100 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
7 documented codes
6 most common
1 DIY-safe checks
5 engineer needed

The 6 most common faults

01
Lockout High DIY-safe

Your boiler has stopped working because it failed to light or stay lit, and it needs a manual restart to try again.

What to try first

Locate the reset button (marked 25 on your control panel).Press and hold the reset button for 2-3 seconds.Wait to see if the boiler ignites and the red light stops flashing.

Est. cost
£100-250
Parts
Ignition electrode, Gas valve, Flame rectification probe
Full guide for Lockout
02
Red indicator High Engineer

Your boiler has stopped working because it cannot light the gas burner or keep it burning.

Est. cost
£120-250
Parts
Ignition electrode, Gas valve, Flame sensor
Full guide for Red indicator
03
Red lockout indicator High Engineer

Your boiler has failed to light the flame, so it has safely shut itself down to prevent gas from building up.

Est. cost
£120-250
Parts
Ignition electrode, Flame sensor, Gas valve
Full guide for Red lockout indicator
04
Red indicator (22) High Engineer

Your boiler has stopped working because it cannot light the internal flame or detect that it is staying lit, so it has shut down for safety.

Est. cost
£120-250
Parts
Ionisation electrode, Ignition lead, Gas valve
Full guide for Red indicator (22)
05
Overheat detection High Engineer

Your boiler has shut itself down because it detected that it is running too hot, indicating a potential circulation or sensor problem.

Est. cost
£120-250
Parts
Overheat thermostat, Pump, Diverter valve
Full guide for Overheat detection
06
Red LED High Engineer

Your boiler has stopped working because it failed to start or got too hot, and it now needs to be manually restarted to begin operating again.

Est. cost
£120-250
Parts
Ignition electrode, Flame rectification probe, Overheat thermostat
Full guide for Red LED

on the Chaffoteaux 80/100

Ignition electrodeGas valveFlame rectification probeFlame sensorPCBIonisation electrode

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Chaffoteaux shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 7-code list for the Chaffoteaux 80/100