Common problems guide

The most common Daikin Altherma Hybrid EHYKOMB33 problems

The faults most likely to send a Daikin Altherma Hybrid EHYKOMB33 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

24 documented codes
6 most common
3 DIY-safe checks
3 engineer needed

The 6 most common faults

01
40 High DIY-safe

Your boiler has detected that the water pressure in the system is too low for it to operate safely.

What to try first

Locate the filling loop (a flexible silver hose) underneath or near the boiler.Slowly open the valves on the filling loop until you hear water moving.Watch the pressure gauge and close the valves once it reaches between 1.0 and 1.5 bar.

Est. cost
£0-120
Parts
Filling loop valves, Expansion vessel, Pressure sensor
Full guide for 40
02
4 High DIY-safe

Your boiler is failing to light the gas even though it is trying to start up.

What to try first

Check that your gas emergency control valve (usually by the meter) is in the 'on' positionCheck if other gas appliances in your home, like a hob, are working correctlyRestart the boiler using the reset button to see if it was a temporary glitch

Est. cost
£120-350
Parts
Ignition electrode, Gas valve, Ignition transformer
Full guide for 4
03
5 High DIY-safe

Your boiler is struggling to keep its flame lit, which is usually caused by a blockage in the drainage pipe or an incorrect gas supply.

What to try first

Check the external white plastic condensate pipe for signs of freezing or blockages.If the pipe is frozen, gently pour warm (not boiling) water over it to thaw the ice.Restart the boiler using the reset button to see if the flame stays lit.

Est. cost
£100-250
Parts
Ionisation electrode, Gas valve, Condensate trap
Full guide for 5
04
0 High Engineer

Your system has detected a potential electronic reading error during its routine startup check and has stopped working to prevent further issues.

Est. cost
£180-350
Parts
Temperature sensor, PCB control board, Wiring harness
Full guide for 0
05
1 High Engineer

Your hybrid system has detected that the water temperature inside the unit is getting too hot, so it has temporarily shut down to prevent damage.

Est. cost
£150-350
Parts
Flow sensor, Circulation pump, Temperature thermistor
Full guide for 1
06
2 High Engineer

The system's control sensors have been incorrectly wired or swapped during installation or maintenance, preventing the boiler from correctly reading temperatures.

Est. cost
£120-200
Parts
Wiring harness, Control board connector
Full guide for 2

on the Daikin Altherma Hybrid EHYKOMB33

Filling loop valvesExpansion vesselPressure sensorIgnition electrodeGas valveIgnition transformer

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Daikin shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 24-code list for the Daikin Altherma Hybrid EHYKOMB33