14 High

Daikin 14 Fault Code

The Daikin 14 fault code means: your boiler has detected trapped air in the pipes or a fault with the sensor that monitors water temperature, causing the system to stop working to avoid overheating.. It appears on 3 Daikin models in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: Sensor fault S1: Air in the installation. Purge the air from the boiler and CH installation. Check the connection of the ntc on the hot water tube. Check wiring for break. Replace S1.
Typical repair cost £90-180 (including labour)

DIY fix possible

Check the system pressure is between 1.0 and 1.5 barBleed all radiators in the house to release trapped airLocate the manual air vent on the boiler to ensure air is purgedReset the boiler by pressing the reset button