Common problems guide

The most common ECA Confeo Premix HCH problems

The faults most likely to send a ECA Confeo Premix HCH into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

38 documented codes
6 most common
5 DIY-safe checks
1 engineer needed

The 6 most common faults

01
E01 High DIY-safe

Your boiler has failed to light because it cannot detect a gas supply or a flame, resulting in the system shutting down for safety.

What to try first

Check that your gas meter is topped up and the emergency control valve is in the 'on' positionVerify if other gas appliances in your home, such as a hob, are working correctlyPress and hold the 'Reset' button for 3 to 5 seconds to clear the fault

Est. cost
£100-280
Parts
Ignition electrode, Gas valve, Printed Circuit Board (PCB)
Full guide for E01
02
E02 High DIY-safe

Your boiler thinks a flame is burning even though it hasn't released any gas yet, which has caused it to shut down for safety.

What to try first

Locate the 'Reset' button on the boiler control panel.Press and hold the Reset button for 3 seconds.Wait to see if the boiler restarts; if the error returns immediately, call a gas safe engineer.

Est. cost
£120-280
Parts
Ionisation Electrode, Gas Valve, Main PCB
Full guide for E02
03
E03 High DIY-safe

Your boiler has shut down because the water inside has become too hot, which is usually caused by a blockage or restricted water flow.

What to try first

Check that all radiator valves are fully open.Ensure the boiler's service valves (underneath) are in the open position.Press the 'Reset' button on the control panel to restart the system.

Est. cost
£100-350
Parts
Circulation Pump, Overheat Thermostat, NTC Temperature Sensor
Full guide for E03
04
E15 High DIY-safe

Your boiler has shut itself down because it is receiving conflicting readings from its internal temperature sensors.

What to try first

Press and hold the 'Reset' button for 3 seconds to clear the lockoutCheck if your radiators are bled and the system pressure is between 1.0 and 1.5 barIf the code returns immediately after resetting, you must call a Gas Safe engineer

Est. cost
£90-180
Parts
NTC Temperature Sensor, Flow/Return Thermistor, Control Board (PCB)
Full guide for E15
05
E17 High Engineer

Your boiler has stopped working because it cannot detect any temperature readings from the pipe that brings water back into the unit.

Est. cost
£90-180
Parts
Return temperature sensor (NTC thermistor), Wiring harness / sensor connections
Full guide for E17
06
E18 High DIY-safe

Your boiler has detected an unusually rapid rise in temperature and has shut down as a safety precaution to prevent overheating.

What to try first

Press the Reset button on the control panel onceCheck that all radiator valves are fully open to allow water to circulateEnsure your system pressure is topped up to between 1.0 and 1.5 bar

Est. cost
£120-250
Parts
Temperature Sensor (NTC thermistor), Circulation Pump, Heat Exchanger (cleaning or replacement)
Full guide for E18

on the ECA Confeo Premix HCH

Ignition electrodeGas valvePrinted Circuit Board (PCB)Ionisation ElectrodeGas ValveMain PCB

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The ECA shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 38-code list for the ECA Confeo Premix HCH