Common problems guide

The most common ECA Confeo Premix HST problems

The faults most likely to send a ECA Confeo Premix HST into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

38 documented codes
6 most common
5 DIY-safe checks
1 engineer needed

The 6 most common faults

01
E01 High DIY-safe

Your boiler has failed to light because it isn't detecting a gas supply or a flame, leaving you without heating and hot water.

What to try first

Check that your gas emergency control valve (usually near the meter) is in the 'on' position.Verify if other gas appliances in your home, such as a hob, are working correctly to rule out a network issue.Press and hold the 'Reset' button for 3 seconds to see if the boiler restarts.

Est. cost
£100-£280
Parts
Ignition electrode, Gas valve, Flame sensing cable
Full guide for E01
02
E02 High Engineer

Your boiler thinks it sees a flame even though it hasn't turned the gas on yet, causing it to shut down for safety.

Est. cost
£120-350
Parts
Ionisation Electrode, Gas Valve, Printed Circuit Board (PCB)
Full guide for E02
03
E03 High DIY-safe

Your boiler has shut down because the internal water temperature has become too hot.

What to try first

Check that at least one radiator (usually one without a thermostatic valve) is fully turned on.Ensure the blue and red water valves underneath the boiler are in the open position.Wait 10 minutes for the unit to cool down and then press the Reset button.

Est. cost
£120-350
Parts
Circulation pump, Heat exchanger (chemical flush), NTC Temperature sensors
Full guide for E03
04
E15 High DIY-safe

Your boiler has shut down because its internal temperature sensors are giving conflicting readings and can no longer monitor the heat safely.

What to try first

Locate the Reset button on the boiler control panelPress and hold the Reset button for 3 secondsWait for the boiler to restart; if the code returns, you must call a Gas Safe engineer

Est. cost
£100-190
Parts
NTC Temperature Sensor (Flow), NTC Temperature Sensor (Return), Connecting Wiring Loom
Full guide for E15
05
E16 High DIY-safe

Your boiler has stopped working because it cannot detect the temperature of the water flowing into your heating system.

What to try first

Press the 'Reset' button on the boiler control panel onceWait 5 minutes to see if the error code clears and the boiler fires upIf the code returns immediately, do not attempt further repairs and contact a professional

Est. cost
£90-160
Parts
Central Heating Flow NTC Sensor, Wiring harness / sensor connection
Full guide for E16
06
E17 High DIY-safe

Your boiler has shut down because it cannot detect any water temperature information coming back from your heating system pipes.

What to try first

Locate the Reset button on the boiler control panel.Press and hold the Reset button for 3 to 5 seconds.Wait for the boiler to restart; if the code returns immediately, a professional repair is required.

Est. cost
£90-160
Parts
Return Temperature Sensor (NTC Thermistor), Sensor Wiring Harness
Full guide for E17

on the ECA Confeo Premix HST

Ignition electrodeGas valveFlame sensing cablePrinted Circuit Board (PCB)Ionisation ElectrodeGas Valve

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The ECA shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 38-code list for the ECA Confeo Premix HST