Low
FH on Ferroli Arean

Your boiler is currently performing a brief automatic self-test to clear any trapped air from the system and will usually resume normal operation on its own after two minutes.

Monitor it

This is a minor fault. Keep an eye on it and mention it at your next annual boiler service. Reset the boiler and see if it clears.

Technical description

Air purge function (active for the first 120 seconds after ignition)

DIY fix possible

Wait for 120 seconds to allow the automated air purge cycle to complete.Do not turn off or reset the boiler while this light is displayed.If the code does not disappear after two minutes, check that your system pressure is at the correct level (typically 1-1.5 bar) and top it up if necessary.