Common problems guide

The most common Ferroli Optimax HE Plus problems

The faults most likely to send a Ferroli Optimax HE Plus into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
21 documented codes
6 most common
2 DIY-safe checks
4 engineer needed

The 6 most common faults

01
F37 High DIY-safe

Your boiler has stopped working because the water pressure inside the heating system has dropped too low to operate safely.

What to try first

Locate the external filling loop (a flexible silver hose connecting two pipes near the boiler).Open the valves at both ends of the hose to let mains water into the system.Monitor the boiler's pressure gauge until the needle reaches the green zone (typically 1.0 to 1.5 bar).Close both valves tightly and remove the filling loop if required by your specific model.

Est. cost
£80-150
Parts
Pressure relief valve, Expansion vessel, Pressure sensor
Full guide for F37
02
Low system pressure High DIY-safe

Your boiler has stopped working because the amount of water inside your heating system has dropped too low to operate safely.

What to try first

Locate the external filling loop, which is a flexible braided hose underneath the boiler.Open the valves at both ends of the hose to allow water into the system until the pressure gauge reads between 1 and 1.5 bar.Ensure both valves are tightly closed and check for any visible leaks on your radiators or pipework.

Est. cost
£80-120
Parts
Filling loop, Pressure relief valve, Pressure gauge
Full guide for Low system pressure
03
A01 High Engineer

Your boiler is trying to start up but cannot successfully light the internal flame to provide heat or hot water.

Est. cost
£120-250
Parts
Ignition electrode, Gas valve, Condensate trap
Full guide for A01
04
A03 High Engineer

Your boiler has detected that it is running too hot and has automatically turned itself off to prevent damage.

Est. cost
£120-250
Parts
NTC sensor, System pump, Heat exchanger
Full guide for A03
05
A04 High Engineer

Your boiler has detected multiple issues with its internal temperature sensing or airflow, causing it to lock itself down for safety.

Est. cost
£150-300
Parts
Temperature sensors, Flue fan, Air pressure switch
Full guide for A04
06
A05 High Engineer

Your boiler has stopped working because it cannot detect if the fan, which is essential for safely venting exhaust gases, is spinning correctly.

Est. cost
£150-250
Parts
Fan unit, Wiring harness, PCB
Full guide for A05

on the Ferroli Optimax HE Plus

Pressure relief valveExpansion vesselPressure sensorFilling loopPressure gaugeIgnition electrode

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Ferroli shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 21-code list for the Ferroli Optimax HE Plus