Ferroli A08 Fault Code
The Ferroli A08 fault code means: your boiler has stopped working because it cannot detect a rise in temperature when it tries to heat your water, suggesting a sensor is failing to report its readings correctly.. It appears on 4 Ferroli models in our database.
Technical description: Heating sensor or domestic hot water sensor disconnected from the flow pipe (normally, after a 5-minute heating order, the temperature increases on the flow pipe sensor and on the domestic hot water sensor do not exceed 3°C. No temperatures above 40°C are detected).
Engineer required
This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.
Find a Gas Safe engineer
Search the official register for a qualified engineer in your area.
Gas Safe Register →Avoid the next call-out bill
A cover plan would handle faults like A08: no call-out fees, no surprise bills.
Affiliate links. We may earn a commission at no extra cost to you.
Ferroli models that show the A08 fault code
Click a model for the full fault code list and model-specific repair notes.
Source
Ferroli A08 fault code information on this page is sourced and cross-checked against the official Ferroli service / installation manuals for each affected model.
- Ferroli Bluehelix HiTech RRT manual →
- Ferroli Bluehelix Tech RRT manual →
- Ferroli Leb TS manual (PDF)
Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 31 August 2026