Ferroli LED 6 Fault Code
Also written as LED6 — same fault.
The Ferroli LED 6 fault code means: your boiler has detected that there is not enough water inside the system to operate safely, so it has turned itself off to prevent damage.. It appears on 3 Ferroli models in our database.
Technical description: Low water pressure switch - WARNING
DIY fix possible
Locate the filling loop, which is usually a flexible silver hose connected to two valves under the boiler.Open the valves slowly to allow water into the system until the pressure gauge on the front of the boiler reads between 1.0 and 1.5 bar.Close the valves firmly and check for any leaks around the connection points.
Find a Gas Safe engineer
Search the official register for a qualified engineer in your area.
Gas Safe Register →Ferroli models that show the LED 6 fault code
Click a model for the full fault code list and model-specific repair notes.
Source
Ferroli LED 6 fault code information on this page is sourced and cross-checked against the official Ferroli service / installation manuals for each affected model.
Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026