Common problems guide

The most common Ferroli i25 problems

The faults most likely to send a Ferroli i25 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

18 documented codes
6 most common
3 DIY-safe checks
3 engineer needed

The 6 most common faults

01
A01 High DIY-safe

Your boiler has failed to light the flame, which means you currently have no heating or hot water.

What to try first

Check if other gas appliances, like a cooker, are working to confirm your gas supply is on.If it is a freezing day, ensure your external condensate pipe is not frozen and blocked.Press the 'Reset' button on the boiler control panel to attempt a restart.

Est. cost
£100-350
Parts
Ignition Electrode, Gas Valve, PCB (Main Board)
Full guide for A01
02
F37 High DIY-safe

Your boiler has stopped working because the water pressure inside the system has dropped too low and needs topping up.

What to try first

Locate the filling loop (usually a silver flexible hose) underneath the boiler.Slowly open the small valve handles until you hear water entering the system.Watch the pressure gauge and close both valves firmly once it reaches 1.5 bar.

Est. cost
£0-120
Parts
Filling loop, Water pressure switch, Expansion vessel
Full guide for F37
03
F43 High DIY-safe

Your boiler has switched itself off because the water inside is getting too hot too quickly, usually because the water isn't moving through the pipes properly or there is trapped air.

What to try first

Check that your central heating valves and radiator valves are fully openBleed your radiators to remove any trapped air from the systemEnsure the system water pressure is between 1.0 and 1.5 bar on the gaugeReset the boiler by pressing the 'Reset' button

Est. cost
£120-£350
Parts
Central heating pump, Automatic air vent, Main heat exchanger (if scaled up)
Full guide for F43
04
A02 High Engineer

Your boiler thinks a flame is burning even though it is supposed to be turned off, which causes it to shut down for safety.

Est. cost
£120-350
Parts
Ionisation Electrode, Flame Sensing Cable, Main PCB
Full guide for A02
05
A03 High Engineer

Your boiler has switched itself off because it has detected that the water inside has become dangerously hot or a temperature sensor has failed.

Est. cost
£90-180
Parts
Heating temperature sensor (NTC probe), Circulation pump, Overheat thermostat
Full guide for A03
06
A06 High Engineer

Your boiler is failing to keep the flame lit after it starts up, which is usually caused by an issue with the gas supply or a blocked internal part.

Est. cost
£120-280
Parts
Gas valve, Electrode, Condensate trap
Full guide for A06

on the Ferroli i25

Ignition ElectrodeGas ValvePCB (Main Board)Filling loopWater pressure switchExpansion vessel

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Ferroli shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue