Common problems guide

The most common Ferroli i29 problems

The faults most likely to send a Ferroli i29 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

18 documented codes
6 most common
3 DIY-safe checks
3 engineer needed

The 6 most common faults

01
A01 High DIY-safe

Your boiler is failing to start because it cannot detect a flame, meaning you have no heating or hot water.

What to try first

Check if your gas supply is active by testing another gas appliance like a hob.Check for credit on your prepaid gas meter, if applicable.Press the Reset button on the boiler control panel once.Ensure the condensate drain pipe outside isn't frozen if the weather is extremely cold.

Est. cost
£90-£350
Parts
Ignition Electrode, Gas Valve, PCB (Main Circuit Board)
Full guide for A01
02
F37 High DIY-safe

Your boiler has detected that the water pressure is too low for it to operate safely, which is usually fixed by topping up the system.

What to try first

Locate the external filling loop (braided silver hose) usually found underneath the boiler.Slowly open the small valves at either end of the hose until you hear water flowing.Watch the pressure gauge and close the valves once the needle reaches between 1.0 and 1.5 bar.

Est. cost
£0-160
Parts
Water pressure switch, External filling loop
Full guide for F37
03
F43 High DIY-safe

Your boiler has stopped working because water is not moving through the system properly or there is too much air trapped inside.

What to try first

Check that the radiator valves are openBleed all radiators to remove trapped airCheck the boiler pressure gauge and top up to 1.5 bar if lowRestart the boiler using the Reset button

Est. cost
£100-£350
Parts
Circulation pump, Automatic air vent, Main heat exchanger (if scaled)
Full guide for F43
04
A02 High Engineer

Your boiler thinks a flame is burning even when it’s supposed to be turned off, which causes it to shut down as a safety precaution.

Est. cost
£120-350
Parts
Ionisation Electrode, Flame Sensing Cable, Main PCB
Full guide for A02
05
A03 High Engineer

Your boiler has sensed it is getting too hot and has shut itself down as a safety precaution to prevent damage.

Est. cost
£100-220
Parts
Heating temperature sensor (NTC), Circulation pump, Overheated safety thermostat
Full guide for A03
06
A06 High Engineer

Your boiler is failing to keep a flame alight after starting up, which usually means it isn't getting enough gas or the flame isn't being detected correctly.

Est. cost
£120-280
Parts
Gas Valve, Ignition/Ionisation Electrode, PCB
Full guide for A06

on the Ferroli i29

Ignition ElectrodeGas ValvePCB (Main Circuit Board)Water pressure switchExternal filling loopCirculation pump

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Ferroli shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill