High
F45 on Ferroli Optima 201

Your boiler has detected a problem with the sensor that monitors the temperature and safety of the exhaust gasses, causing it to stop working to keep you safe.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description

Flue sensor fault

Engineer required

This is a high severity fault. Stop using the boiler and call a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.

Find a Gas Safe engineer
Search the official register →

Related fault codes

Related guides you might find useful