User interface fault
Glow-worm Betacom2 28 Fault codes & diagnostics
58 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.
The fault code is already on your display
Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →
Severity at a glance
Each cell = one fault code. Hover to identify.Which version do you have?
The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.
| GC number | Appliance (register name) | Produced |
|---|---|---|
| 47-019-17 | Betacom2 28 | 2012–present |
Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.
All 58 documented codes
Tap any card for details
Flow heating temperature sensor fault
Return heating temperature sensor fault
Flow heating temperature sensor fault
Return heating temperature sensor fault
Overheating fault
Water pressure of the installation (<0.3 bar)
Maximum temperature difference reached between return and flow heating
Water circulation fault
Fault in gas valve motor.
Flame detection fault.
The burner fails to ignite
Loss of flame during operation
Incorrect air pressure
EBUS voltage fault
Fault in the main board
Gas valve closure fault
Fault in the main board memory
Rapid fluctuation of return or flow heating sensor
Excessive main board temperature
Flame signal fault in the main board
Fluctuation of flame signal
User interface incompatible with the main board
Flow heating temperature sensor fault
Permanent temperature difference between flow and return heating sensors
Heating circuit pressure sensor fault
Heating circuit pressure sensor fault
Thermal fuse fault
Fault in gas valve motor
No water in the installation : the temperature does not increase when the burner is lit
Permanent temperature difference between flow and return heating sensors
Flow and return heating sensors fault
Underfloor heating contact fault
No request for heating
Pre-run fan
Pre-run pump
Ignition
Burner lit
Post run pump/fan
Post run fan
Post run pump
Time delay anti short-cycles after heating
Request for domestic hot water
Pre-run fan
Ignition
Burner lit
Post run pump/fan
Post run fan
Post run pump
Default status, no request for heating or domestic water. If an EBUS controller is connected to the boiler, check that a wiring link is present on terminals 3 and 4 of the boiler's main board.
"Hot water only" mode
Control cycle: the speed of the fan in the functioning phase is outside tolerance.
"Frost protection" mode
Water pressure too high
Waiting cycle: temperature differential between heating flow and return is too high. If ∆T > 30, forcing to Pmin.
Waiting cycle: lack of water in the installation/temperature rise between heating flow and return is too high.
Test temperature sensor for heating return.
Test temperature sensors for heating flow and return, or the appliance has a fault.
Avoid the next call-out bill
Monthly cover means no unexpected bills when your boiler breaks down.
Affiliate links. We may earn a commission at no extra cost to you.