Glow-worm P.05 Fault Code
Also written as P05 — same fault.
The Glow-worm P.05 fault code means: your boiler is currently performing an automatic air-removal process after detecting a change in water pressure, and it will return to normal operation once this cycle finishes.. It appears on 10 Glow-worm models in our database.
Technical description: Filling the product: The diverter valve is moved to the mid-position. The burner and pump are switched off (to fill or drain the product). If the pressure is lower than 0.05 MPa (0.5 bar) and then is above 0.07 MPa (0.7 bar) for longer than 15 seconds, the automatic purging function is activated. The function is activated for 15 minutes.
DIY fix possible
Wait for 15 minutes to allow the automatic purging cycle to completeCheck your boiler's pressure gauge to ensure it is between 1.0 and 1.5 barIf the pressure is below 1.0 bar, use the filling loop to top it up to the correct level
Find a Gas Safe engineer
Search the official register for a qualified engineer in your area.
Gas Safe Register →Avoid the next call-out bill