Glow-worm Energy2 30c Fault codes & diagnostics
87 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.
The fault code is already on your display
Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →
Severity at a glance
Each cell = one fault code. Hover to identify.Which version do you have?
The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.
| GC number | Appliance (register name) | Produced |
|---|---|---|
| 47-019-38 | Energy2 30c -A (P-GB) | 2018–present |
Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.
All 87 documented codes
Tap any card for details
Fault: Flow temperature sensor
Fault: Return temperature sensor
Short circuit: Flow temperature sensor
Short circuit: Return temperature sensor
Short circuit: Cylinder temperature sensor
Short circuit: Temperature sensor for the domestic hot water cylinder
Safety shutdown: Overheating temperature reached
Safety shutdown: Water deficiency in the boiler
Safety shutdown: Temperature spread too great (NTC1/NTC2)
Safety shutdown: Temperature rise too fast
Safety shutdown: Flue gas temperature too high
Safety shutdown: Fault in flame detection
Fault: Ignition unsuccessful when starting up
Fault: Flame loss
Fan frost protection function active: Fan speed outside the tolerance values
eBUS fault: Voltage too low
Fault: Gas valve assembly control
Fault: Gas valve switch-off control
Fault: EEPROM
Fault: Electronics/sensor/analogue-to-digital converter
Fault: Electronics temperature too high
Values sent back by ASIC is incorrect (flame signal)
Fault: Unstable flame (analogue input)
Invalid product code (DSN)
Fault: Flow/return temperature sensor
Fault: Deviation in the water pressure sensor/return temperature sensor
Fault: Water pressure sensor not connected or has short-circuited
Fault: Electrical problem in the water pressure sensor
Fault: Pressure sensor
The safety cut-out in the primary heat exchanger is defective
Fault: Condensate or smoke
Interruption to DHW outlet sensor at external control
Fault: Dryfire; Whentheburnerstarts,thetemperaturechangeregisteredattheflowor returntemperaturesensorisnon-existentortoosmall
Fault: Flow/returntemperaturesensor; Valuesnotconsistent,difference<-6K
Fault: Temperaturesensor; Theflowand/orreturntemperaturesensorshavebeeninstalledonthesame pipe/incorrectpipe
Fault: Underfloorheatingcontact; Underfloorheatingcontactopen,sensordisconnectedordefective
Fault: Electrodes; Electrodesnotconnectedortheyareconnectedincorrectly,shortcircuitinthecableharness
Fault: Gasvalveassembly; Gasvalveassemblynotconnectedoritisconnectedincorrectly,shortcircuit inthecableharness
Fault: Pump; Pumpnotconnectedoritisconnectedincorrectly,incorrectpumpconnec- ted,shortcircuitinthecableharness
Short circuit: Cylinder temperature sensor
Fault: MainPCBself-testfailed; MainPCBdefective
Low water pressure (product switches off)
Heating mode: No requirement
Heating mode: Fan prerun
Heating mode: Pump prerun
Heating mode: Burner ignition
Heating mode: Burner on
Heating mode: Pump/fan overrun
Heating mode: Fan overrun
Heating mode: Pump overrun
Heating mode: Temporary shutdown after heating procedure
Domestic hot water mode: Requirement
Domestic hot water mode: Fan prerun
Domestic hot water mode: Burner ignition
DHW mode: Burner on
DHW mode: Pump/fan overrun
DHW mode: Fan overrun
DHW mode: Pump overrun
Domestic hot water mode: Requirement
Domestic hot water mode: Fan prerun
Domestic hot water mode: Pump prerun
Domestic hot water mode: Burner ignition
DHW mode: Burner on
DHW mode: Pump/fan overrun
DHW mode: Fan overrun
DHW mode: Pump overrun
Domestic hot water mode: Temporary shutdown of the burner
Room thermostat is blocking heating mode.
No heating demand: Summer mode, eBUS control, waiting period
Fan waiting time: Fan speed outside of the tolerance values
Forced fan operation until the pressure monitor is switched
Frost protection active
Underfloor heating contact open
Water pressure too high
Flue non-return flap closed
Frost protection mode (Comfort): Minimum load
Product in waiting period/operating block function due to water deficiency (flow/return spread too large)
Waiting period: Water deficiency in the circuit (flow/return spread too large)
Maintenance message: Check the water pressure
Product purging active
Maintenance: Demo mode
Automatic test programme: Return temperature sensor, heating demands blocked.
Automatic test programme: Water pressure sensor, heating demands blocked.
Automatic test programme: Return temperature sensor, heating demands blocked.
Internal automatic test programmes
Purging the combustion cha