LOW PRESSURE High

Grant LOW PRESSURE Fault Code

Also written as LOWPRESSURE — same fault.

The Grant LOW PRESSURE fault code means: the water pressure inside your heating system has dropped too low, so the boiler has turned itself off to prevent any damage.. It appears on 5 Grant models in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: The red indicator on the control panel will flash and the boiler pressure cut-out switch will activate if the water pressure falls below 0.2 bar.
Typical repair cost £80-150 (including labour)

DIY fix possible

Locate the external filling loop, which is usually a flexible silver hose connecting two valves near your boiler.Open the valves on both ends of the hose to allow water into the system until the pressure gauge needle reaches between 1.0 and 1.5 bar.Close both valves tightly and remove the hose if required by your specific installation.