The most common Intergas Combi Compact HRE SB problems

The faults most likely to send a Intergas Combi Compact HRE SB into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
44 documented codes
6 most common
0 DIY-safe checks
6 engineer needed

The 6 most common faults

01
12 High Engineer

Your boiler has detected a problem with its primary temperature sensor and has stopped working as a safety precaution.

Why it happens: This fault occurs when the boiler's main flow sensor, which monitors the temperature of the water leaving the heat exchanger, fails to provide a consistent or logical reading. The most common reason is that the internal electrical component of the sensor has worn out or developed a short circuit, preventing the control board from knowing if the water is at a safe temperature.

Est. cost
£90-160
Parts
Flow temperature sensor (S1), Sensor wiring harness
Full guide for 12
02
13 High Engineer

Your boiler has detected a problem with its primary temperature sensor and has stopped working as a safety precaution.

Why it happens: This fault occurs when the boiler's main flow sensor, which monitors the temperature of the water leaving the heat exchanger, fails to provide a consistent or logical reading. The most common reason is that the internal electrical component of the sensor has worn out or developed a short circuit, preventing the control board from knowing if the water is at a safe temperature.

Est. cost
£90-160
Parts
Flow temperature sensor (S1), Sensor wiring harness
Full guide for 13
03
14 High Engineer

Your boiler has detected a problem with its primary temperature sensor and has stopped working as a safety precaution.

Why it happens: This fault occurs when the boiler's main flow sensor, which monitors the temperature of the water leaving the heat exchanger, fails to provide a consistent or logical reading. The most common reason is that the internal electrical component of the sensor has worn out or developed a short circuit, preventing the control board from knowing if the water is at a safe temperature.

Est. cost
£90-160
Parts
Flow temperature sensor (S1), Sensor wiring harness
Full guide for 14
04
20 High Engineer

Your boiler has detected a problem with the temperature sensor that monitors the water returning to the unit, causing it to stop running for safety.

Why it happens: This fault occurs when the boiler's internal computer stops receiving a reliable temperature reading from the sensor on the return pipe. It is usually caused by the sensor itself failing, or a loose connection in the wiring that prevents the signal from reaching the control board. For safety, the boiler shuts down because it can no longer monitor if the water returning from your radiators is at a safe temperature.

Est. cost
£90-180
Parts
NTC Temperature Sensor (S2), Sensor wiring harness, External sensor
Full guide for 20
05
21 High Engineer

Your boiler has detected a problem with the temperature sensor that monitors the water returning to the unit, causing it to stop running for safety.

Why it happens: This fault occurs when the boiler's internal computer stops receiving a reliable temperature reading from the sensor on the return pipe. It is usually caused by the sensor itself failing, or a loose connection in the wiring that prevents the signal from reaching the control board. For safety, the boiler shuts down because it can no longer monitor if the water returning from your radiators is at a safe temperature.

Est. cost
£90-180
Parts
NTC Temperature Sensor (S2), Sensor wiring harness, External sensor
Full guide for 21
06
23 High Engineer

Your boiler has detected a problem with the temperature sensor that monitors the water returning to the unit, causing it to stop running for safety.

Why it happens: This fault occurs when the boiler's internal computer stops receiving a reliable temperature reading from the sensor on the return pipe. It is usually caused by the sensor itself failing, or a loose connection in the wiring that prevents the signal from reaching the control board. For safety, the boiler shuts down because it can no longer monitor if the water returning from your radiators is at a safe temperature.

Est. cost
£90-180
Parts
NTC Temperature Sensor (S2), Sensor wiring harness, External sensor
Full guide for 23

on the Intergas Combi Compact HRE SB

Flow temperature sensor (S1)Sensor wiring harnessNTC Temperature Sensor (S2)External sensor

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Intergas shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 44-code list for the Intergas Combi Compact HRE SB