Low system pressure High

Potterton Low system pressure Fault Code

Also written as LOWSYSTEMPRESSURE — same fault.

The Potterton Low system pressure fault code means: your central heating system has lost the water pressure it needs to circulate heat, which will prevent the boiler from running until it is topped back up.. It appears on 2 Potterton models in our database.

Call an engineer soon

Book a Gas Safe engineer within 24 to 48 hours. Your boiler may be unsafe or could break down completely if left.

Technical description: System pressure is less than 0.5 bar. Pressurise the system to 1.5 bar.

DIY fix possible

Locate the filling loop (usually a silver flexible hose) underneath the boiler or near the heating pipes.Open the valves at both ends of the hose to let mains water into the system.Monitor the pressure gauge on the front of the boiler until the needle reaches 1.5 bar, then securely close both valves.

Find a Gas Safe engineer

Search the official register for a qualified engineer in your area.

Gas Safe Register →

Potterton models that show the Low system pressure fault code

Click a model for the full fault code list and model-specific repair notes.

Source

Potterton Low system pressure fault code information on this page is sourced and cross-checked against the official Potterton service / installation manuals for each affected model.

Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026