Potterton Kingfisher Mf RSL60 Fault codes & diagnostics

25 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Regular Natural Gas 2001-2006 Discontinued
GC Number 41-590-37
Download the Potterton Kingfisher Mf RSL60 manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
5 Emergency 20 High

All 25 documented codes

Tap any card for details

E02-234

Your boiler is failing to light because it cannot detect or supply the correct amount of gas for the burner to operate safely.

Emergency Engineer only £150-£300

Parts commonly replaced

  • Gas valve
  • Burner injector
  • Ignition electrode
E02-313

Your boiler has detected that a seal around the internal fan unit has failed or is leaking, which prevents the system from safely venting gases.

Emergency Engineer only £150-250

Parts commonly replaced

  • Fan Gasket
  • Fan Assembly
E02-325

Your boiler has stopped working because a sensor that monitors water temperature is not sending the correct signal to the control system.

High Engineer only £120-220

Parts commonly replaced

  • NTC Thermistor
  • Wiring harness
E02-347

Your boiler has failed to light the flame properly, meaning it cannot produce heat or hot water because the ignition system is not functioning.

High Engineer only £150-300

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB
E02-348

Your boiler is failing to ignite correctly because the gas flow mechanism is restricted or faulty, preventing it from heating your home.

High Engineer only £150-250

Parts commonly replaced

  • Gas valve
  • Injector
  • Burner seal
E02-349

Your boiler has failed to ignite because the gas supply reaching the burner is not at the correct pressure or is being blocked, preventing it from heating your home.

High Engineer only £150-250

Parts commonly replaced

  • Gas valve
  • Injector assembly
  • Burner manifold
E02-350

Your boiler is failing to ignite or stay lit because the internal gas distribution system is blocked or malfunctioning.

Emergency Engineer only £150-300

Parts commonly replaced

  • Pilot injector
  • Gas valve
  • Thermocouple
E02-365

Your boiler's central control computer is experiencing an internal error, which has caused the system to shut down for your safety.

High Engineer only £250-450

Parts commonly replaced

  • Main printed circuit board (PCB)
E02-367

Your boiler has lost the ability to send electrical signals between its internal parts, meaning it cannot communicate correctly to start heating.

High Engineer only £150-250

Parts commonly replaced

  • Wiring harness
  • PCB
E02-372

Your boiler is failing to ignite because it cannot detect a flame, likely due to a faulty or dirty sensor that helps start the fire.

High Engineer only £150-250

Parts commonly replaced

  • Ignition electrode
  • Flame rectification probe
  • Ignition lead
Showing 11–20 of 25
E02-376

Your boiler has stopped working because it cannot confirm that the internal fan is moving air correctly, which is a vital safety check to ensure exhaust gases are cleared properly.

High Engineer only £150-250

Parts commonly replaced

  • Air Pressure Switch
  • Pressure sensing tubes
  • Fan assembly
E02-379

Your boiler has detected an internal communication error with its main control unit, meaning it is unable to safely manage its heating operations.

High Engineer only £250-450

Parts commonly replaced

  • User Control Interface
  • Printed Circuit Board (PCB)
E02-380

Your boiler is having trouble communicating with its internal temperature controls, which means it cannot accurately sense how hot the water needs to be and has safely shut down to prevent overheating.

High Engineer only £150-250

Parts commonly replaced

  • Potentiometer
  • Wiring harness assembly
  • Printed Circuit Board (PCB)
E03-826

Your boiler's fan, which is responsible for safely venting exhaust gases outside, has stopped working correctly, causing the system to shut down for safety reasons.

High Engineer only £250-400

Parts commonly replaced

  • Fan Assembly
  • Fan Gasket
E03-827

Your boiler's air extraction system is not operating correctly, which prevents the unit from starting the ignition process to keep you safe.

High Engineer only £250-400

Parts commonly replaced

  • Fan assembly
  • Fan gasket
  • Printed Circuit Board
E78-180

Your boiler has detected that exhaust gases are not escaping correctly through the flue, which is a safety mechanism to prevent dangerous fumes from entering your home.

Emergency Engineer only £150-300

Parts commonly replaced

  • TTB/Flue Thermostat
  • Flue assembly components
E78-181

Your boiler has detected that dangerous exhaust gases are not escaping correctly through the flue, so it has shut down for your protection.

Emergency Engineer only £150-300

Parts commonly replaced

  • Flue Thermostat
  • TTB Safety Device
E78-210

Your boiler's burner is failing to ignite or stay lit, meaning your heating and hot water will not work until a professional resolves the issue.

High Engineer only £150-300

Parts commonly replaced

  • Thermocouple
  • Gas valve
  • Ignition electrode
E78-212

Your boiler is failing to light because it cannot detect or maintain an active flame, causing the system to shut down for safety.

High Engineer only £150-300

Parts commonly replaced

  • Thermocouple
  • Ignition lead
  • Gas valve solenoid
E78-236

Your boiler is failing to detect the gas flow required to ignite, meaning it cannot produce heat or hot water because the internal gas supply component is not responding correctly.

High Engineer only £250-450

Parts commonly replaced

  • Gas valve assembly
  • Wiring harness
  • Control PCB
Showing 21–25 of 25
E78-250

Your boiler has detected an issue with its internal airflow system, which is preventing it from safely starting up to provide heat or hot water.

High Engineer only £150-250

Parts commonly replaced

  • Air pressure switch
  • Venturi assembly
  • Flue fan
E78-367

Your boiler has detected an issue with the sensor that confirms the internal fan is moving air correctly, so it has shut down to prevent unsafe operation.

High Engineer only £180-350

Parts commonly replaced

  • Air Pressure Switch
  • Flue fan assembly
  • Silicon pressure tubes
E78-369

Your boiler is failing to detect the airflow needed for safe operation, so it has automatically shut down to prevent it from running incorrectly.

High Engineer only £150-250

Parts commonly replaced

  • Air Pressure Switch
  • Venturi
  • Fan Assembly
E82-317

Your boiler has stopped working because it cannot safely ignite or maintain a flame, meaning you currently have no heating or hot water.

High Engineer only £150-300

Parts commonly replaced

  • Ignition lead
  • Gas valve
  • Flame rectification probe
Flame Lock-out

Your boiler has stopped working because it cannot light the internal flame, which means you currently have no heating or hot water.

High Engineer only £120-250

Parts commonly replaced

  • Thermocouple
  • Gas valve
  • PCB
  • Spark generator