Common problems guide

The most common Potterton Precision problems

The faults most likely to send a Potterton Precision into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
12 documented codes
6 most common
2 DIY-safe checks
4 engineer needed

The 6 most common faults

01
Off Off Off High DIY-safe

The boiler appears to have no power at all, so it isn't producing heating or hot water, but this is usually caused by a switch, fuse or power supply issue that can often be checked safely.

What to try first

Check that the boiler's on/off switch is turned on and that the power switch on the wall (fused spur) is switched on with its fuse intact.Check your consumer unit (fuse box) to see whether the circuit for the boiler has tripped, and reset it if so.Check that the room thermostat or timer is not switching the boiler off, and replace its batteries if it has any.If the boiler still shows no display after these checks, stop and call a Gas Safe registered engineer, as the fault is likely inside the boiler's electrical circuit.

Est. cost
£80-300
Parts
Fused spur or boiler power fuse, Main printed circuit board (PCB), Power supply transformer
Full guide for Off Off Off
02
On Flash Flash High DIY-safe

Your boiler has shut itself down as a safety precaution, most often because it is low on water, so it needs a quick check before it can heat your home again.

What to try first

Check the boiler's pressure gauge with the boiler cold. A reading below 1 bar usually means the system is low on water.If the pressure is low, top it up using the filling loop, following the boiler manual, and watch the gauge until it reaches about 1.5 bar.Close the filling loop, then press the reset button and see whether the boiler restarts.If the code returns, or the pressure keeps dropping, stop and call a Gas Safe registered engineer, as this may point to a leak or a faulty pump or flow switch.

Est. cost
£90-220
Parts
Circulating pump, Flow switch, Diverter valve
Full guide for On Flash Flash
03
On Off On High Engineer

The boiler has stopped trying to light after several failed attempts, so it has shut itself down as a safety precaution and will need to be reset and checked.

Est. cost
£90-280
Parts
Ignition electrode, Flame sensor, Ignition lead
Full guide for On Off On
04
Flash Off On High Engineer

Your boiler has switched itself off to protect itself because it got too hot, and it will need a reset once it has cooled down and the cause has been checked.

Est. cost
£90-200
Parts
Overheat thermistor (NTC sensor), Circulation pump, Heat exchanger (if scaled or blocked)
Full guide for Flash Off On
05
Flash Flash On High Engineer

Your boiler has shut itself down for safety because a part that moves air through it isn't working correctly, so it won't provide heating or hot water until a qualified engineer has looked at it.

Est. cost
£150-350
Parts
Fan assembly, Fan pressure switch, Flue hose or flue seals
Full guide for Flash Flash On
06
On Flash On High Engineer

Your boiler is showing a temperature sensor fault, which usually means it can't read the water temperature correctly and may stop heating or switch itself off as a safety precaution.

Est. cost
£90-180
Parts
Thermistor (flow or return temperature sensor), Sensor wiring or connector, Control PCB (if the sensor is fine but the board is faulty)
Full guide for On Flash On

on the Potterton Precision

Fused spur or boiler power fuseMain printed circuit board (PCB)Power supply transformerOn/off switchCirculating pumpFlow switch

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Potterton shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue
See the full 12-code list for the Potterton Precision