Common problems guide

The most common Potterton Puma 100 problems

The faults most likely to send a Potterton Puma 100 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

5 documented codes
5 most common
3 DIY-safe checks
2 engineer needed

The 5 most common faults

01
Low System Pressure light High DIY-safe

Your boiler has lost the water pressure it needs to circulate heat, so it has safely shut itself down until the system is topped back up.

What to try first

Locate the filling loop (a silver flexi-hose) beneath the boiler.Open the valves on the filling loop to allow water into the system until the pressure gauge reads between 1 and 1.5 bar.Close the valves tightly and turn the boiler off and on again to reset.

Est. cost
£80-150
Parts
Filling Loop, Pressure Relief Valve, Pressure Gauge
Full guide for Low System Pressure light
02
Lockout High DIY-safe

Your boiler has stopped working because it couldn't successfully light the flame after three attempts, often caused by a temporary interruption in the gas supply or air in the lines.

What to try first

Check that your gas supply is turned on at the meter and that other gas appliances are workingLocate the reset button or turn the control knob to the reset position to clear the errorWait for the boiler to cycle through its ignition process automatically

Est. cost
£100-250
Parts
Ignition electrode, Gas valve, PCB
Full guide for Lockout
03
Lockout LED High DIY-safe

Your boiler has shut itself down as a safety precaution because it has detected an internal fault or an interrupted gas supply.

What to try first

Locate the reset button on the front control panel.Press and hold the reset button for several seconds.Check that your gas meter has credit and the isolation valve is open.

Est. cost
£100-350
Parts
Ignition Electrode, Gas Valve, Printed Circuit Board (PCB)
Full guide for Lockout LED
04
Lockout light High Engineer

Your boiler has stopped working because it cannot light its burner or has detected an internal safety problem and shut itself down to prevent damage or risks.

Est. cost
£120-250
Parts
Ignition electrode, Gas valve, Printed Circuit Board (PCB)
Full guide for Lockout light
05
Pilot being extinguished High Engineer

Your boiler's small starter flame has gone out, which has caused the system to shut down for safety because it can no longer safely ignite the main burner.

Est. cost
£120-280
Parts
Thermocouple, Overheat Thermostat, Gas valve
Full guide for Pilot being extinguished

on the Potterton Puma 100

Filling LoopPressure Relief ValvePressure GaugeExpansion VesselIgnition electrodeGas valve

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Potterton shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 5-code list for the Potterton Puma 100