Low Lockout
E10 on Ravenheat CSI 85

Your boiler has too much water in the system, which puts extra stress on the internal components.

Monitor it

This is a minor fault. Keep an eye on it and mention it at your next annual boiler service. Reset the boiler and see if it clears.

Technical description

High water pressure

What causes this fault?

This fault occurs when the water pressure inside your heating system rises above the safe operating limit. The most common reason is that the manual filling loop has been left slightly open or is leaking, allowing fresh water to constantly enter the system. It can also happen if the internal expansion vessel has failed, meaning it can no longer absorb the natural expansion of water as it heats up.

DIY fix possible

Check that the filling loop valves are fully closedBleed water from a radiator using a bleed key to reduce pressureMonitor the pressure gauge until it returns to between 1 and 1.5 barRest the boiler if the code persists