Remeha Avanta Plus 28c Fault codes & diagnostics

22 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Natural Gas 2005-present
GC Number 47-673-02
Download the Remeha Avanta Plus 28c manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
13 High 2 Medium 7 Low

All 22 documented codes

Tap any card for details

8

Your boiler has temporarily paused because the water inside has become slightly hotter than it is supposed to be.

Low Engineer only £90-180

Parts commonly replaced

  • NTC temperature sensor
  • Automatic bypass valve
  • Circulating pump

Related codes

9

Your boiler has temporarily stopped working because a safety switch or external device connected to it, such as a room thermostat or timer, has broken the circuit.

High Engineer only £90-180

Parts commonly replaced

  • External room thermostat
  • Wiring center
  • Timer/programmer
d5

Your boiler has temporarily paused heating because the radiators have already reached the requested temperature, but the thermostat is still asking for heat.

Low DIY-safe

What to check first

  1. Check your room thermostat to see if it is set to a comfortable temperature.
  2. Wait 10 to 15 minutes to see if the boiler automatically restarts once the water cools down.
  3. Ensure your radiator valves are fully open so heat can circulate away from the boiler properly.

Related codes

d8

Your boiler has temporarily stopped because it detected that the water inside is getting hotter than the temperature you have set, likely due to poor circulation.

Medium Engineer only £120-250

Parts commonly replaced

  • Pump
  • Central heating filter
  • System diverter valve

Related codes

d9

Your boiler has switched itself off because the water inside is heating up too quickly or too unevenly, which often happens when water cannot circulate through your radiators properly.

High Engineer only £150-300

Parts commonly replaced

  • Pump
  • Plate heat exchanger
  • Diverter valve

Related codes

é0

Your boiler is perfectly healthy and is simply resting in its normal standby state, waiting for a signal to provide heating or hot water.

Low DIY-safe

What to check first

  1. Check that your room thermostat or programmer is set to a temperature higher than the current room temperature
  2. Ensure your hot water tap is turned on fully if you are testing for hot water

Related codes

E01

Your boiler is trying to start up, but it cannot successfully light the internal flame after several attempts, so it has shut down for safety.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Flame rectification probe

Related codes

é1

Your boiler is currently performing a necessary safety check before it attempts to ignite, but it has stalled at this initial stage.

High Engineer only £120-250

Parts commonly replaced

  • Fan
  • Air pressure switch
  • Printed Circuit Board (PCB)

Related codes

é2

Your boiler is failing to light the flame, which means it cannot produce any heating or hot water for your home.

High Engineer only £150-300

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB

Related codes

Showing 11–20 of 22
é4

Your boiler has failed to light the flame after several attempts and has switched itself off to prevent a build-up of unburnt gas.

High Engineer only £120-250

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ignition transformer

Related codes

é6

Your boiler is continuing to circulate water even though it should have finished, which suggests the system is struggling to reset after heating your home or water.

Low Engineer only £120-250

Parts commonly replaced

  • Pump
  • PCB

Related codes

é7

Your boiler has detected that the water pressure inside the system is far too low to function safely.

High DIY-safe £80-150

What to check first

  1. Locate the filling loop (usually two silver taps connected by a braided hose) underneath the boiler.
  2. Gradually open the taps to let mains water into the heating system until the pressure gauge reads between 1.0 and 1.5 bar.
  3. Close both taps tightly and check the display to see if the error has cleared.

Parts commonly replaced

  • Pressure relief valve
  • Filling loop
  • System pressure sensor

Related codes

é8

Your boiler has detected that the internal fan responsible for venting exhaust gases safely is either not spinning or communicating properly, so it has shut down to keep your home safe.

High Engineer only £180-350

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • Printed Circuit Board (PCB)

Related codes

é10

Your boiler has temporarily stopped working and needs to be manually restarted using the reset button.

High DIY-safe

What to check first

  1. Locate the reset button on your boiler's control panel.
  2. Press and hold the reset button for about 5 seconds.
  3. Wait to see if the boiler fires up normally; if the code returns, do not keep resetting it.

Parts commonly replaced

  • Control PCB
  • Ignition transformer

Related codes

é11

Your boiler has detected that the internal casing is getting too hot, indicating it is struggling to ventilate correctly or is running too hot internally.

High Engineer only £150-350

Parts commonly replaced

  • Fan
  • Air pressure switch
  • Ventilation seals

Related codes

é13

Your boiler has experienced a temporary glitch that has safely shut it down and simply needs to be manually restarted using the reset button.

Low DIY-safe

What to check first

  1. Locate the reset button or key on your Remeha Avanta 28c control panel.
  2. Press and hold the reset button for about 5 seconds.
  3. Wait to see if the boiler fires back up normally; if the code returns, note it down and contact an engineer.

Related codes

é43

Your boiler has detected that some of its internal settings have drifted outside of their safe operating limits, and it has stopped working as a precaution.

High Engineer only £120-250

Parts commonly replaced

  • Main PCB

Related codes

é44

Your boiler has detected an internal software or settings error, which is preventing the system from starting up safely.

High Engineer only £120-250

Parts commonly replaced

  • Control board
  • Parameter key

Related codes

Showing 21–22 of 22
é45

Your boiler has lost its programmed settings and needs to be reconfigured by a professional to operate correctly.

High Engineer only £100-200

Parts commonly replaced

  • Control board

Related codes

OT ERROR

Your boiler's external temperature sensor and frost protection thermostat are sending conflicting signals to your heating controller.

Medium Engineer only £120-200

Parts commonly replaced

  • Outside temperature sensor
  • Frost thermostat
  • Wiring harness

Related codes