Common problems guide

The most common Remeha Quinta Ace 30 problems

The faults most likely to send a Remeha Quinta Ace 30 into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

63 documented codes
6 most common
1 DIY-safe checks
5 engineer needed

The 6 most common faults

01
A02.06 High DIY-safe

Your boiler has detected that the water pressure inside your heating system has dropped too low, which prevents it from working correctly.

What to try first

Locate the external filling loop, which is usually a flexible silver hose connected to two valves under the boiler.Open the valves slowly to allow mains water into the system until the pressure gauge on the boiler front reads between 1.0 and 1.5 bar.Close both valves tightly to prevent over-pressurisation.

Est. cost
£80-120
Parts
Pressure sensor, Filling loop, Pressure relief valve
Full guide for A02.06
02
E00.00 High Engineer

Your boiler has detected a safety issue and has shut itself down completely to prevent damage or danger.

Est. cost
£150-350
Parts
Ignition electrode, Flame sensor, Gas valve
Full guide for E00.00
03
A00.42 High Engineer

Your boiler has stopped working because it cannot detect the water pressure in the system, usually due to a loose wire or a faulty sensor connection.

Est. cost
£120-250
Parts
Water pressure sensor, Wiring harness
Full guide for A00.42
04
A01.23 High Engineer

Your boiler has detected that the fuel and air mixture used to heat your home is not burning correctly, so it has safely shut itself down to prevent unsafe operation.

Est. cost
£150-350
Parts
Ignition electrode, Gas valve, Flue seal
Full guide for A01.23
05
A02.36 High Engineer

Your boiler has lost communication with an internal control module, meaning it cannot safely operate until the connection is restored.

Est. cost
£150-300
Parts
Interface cable, Control PCB, Communication module
Full guide for A02.36
06
A02.37 High Engineer

Your boiler has lost communication with an internal accessory or control component, which is preventing it from operating correctly.

Est. cost
£120-250
Parts
Control board, Communication cable, Internal accessory module
Full guide for A02.37

on the Remeha Quinta Ace 30

Pressure sensorFilling loopPressure relief valveIgnition electrodeFlame sensorGas valve

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Remeha shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 63-code list for the Remeha Quinta Ace 30