980 Low

Remeha 980 Fault Code

The Remeha 980 fault code means: your boiler has paused because the water temperature has risen slightly faster than expected, causing the system to temporarily stop firing as a protective measure.. It appears on 2 Remeha models in our database.

Monitor it

This is a minor fault. Keep an eye on it and mention it at your next annual boiler service. Reset the boiler and see if it clears.

Technical description: The boiler carries out a control stop at a flow temp of 80°C (modulation point + 5°C)

What causes the Remeha 980 fault?

This fault occurs when the water temperature inside the boiler climbs too quickly, causing the system to pause to prevent overheating. The most common reasons are a slight restriction in water flow, such as trapped air or a build-up of sludge, or the circulation pump beginning to tire. It essentially means the heat cannot be moved away from the boiler into your radiators fast enough.

This code often appears during the first cold spell of autumn when the heating is turned on after a long summer break, as pumps can become slightly stiff or stuck.

Typical repair cost £0-120 (including labour)

DIY fix possible

Check that all radiator valves are open to ensure water can flow freely.Inspect the system pressure gauge and top up to 1.5 bar if it is low.Wait for the boiler to cool down, as it should restart automatically once the temperature drops.

Find a Gas Safe engineer

Search the official register for a qualified engineer in your area.

Gas Safe Register →

Remeha models that show the 980 fault code

Click a model for the full fault code list and model-specific repair notes.

Source

Remeha 980 fault code information on this page is sourced and cross-checked against the official Remeha service / installation manuals for each affected model.