Common problems guide

The most common Saunier Duval SD Isotwin Condens F35 E problems

The faults most likely to send a Saunier Duval SD Isotwin Condens F35 E into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

21 documented codes
6 most common
3 DIY-safe checks
3 engineer needed

The 6 most common faults

01
F5 High DIY-safe

Your boiler has switched itself off because it has reached an unsafe temperature to protect the internal components from damage.

What to try first

Check that all radiator valves are fully open to allow water to circulateEnsure the boiler pressure gauge is between 1 and 1.5 barPress the reset button once to see if the fault clears after the system has cooled down

Est. cost
£120-300
Parts
Overheat Thermostat, Circulation Pump, Main Heat Exchanger
Full guide for F5
02
F14 High DIY-safe

Your boiler has shut down because the water inside the central heating system has reached an unsafely high temperature.

What to try first

Check that all radiator valves are fully openEnsure the boiler pressure gauge is between 1.0 and 1.5 barSwitch the boiler off and back on again to reset the system after it has cooled down

Est. cost
£120-350
Parts
Circulating pump, Flow temperature sensor (NTC), Main heat exchanger (flushing/cleaning)
Full guide for F14
03
F23 High DIY-safe

Your boiler has detected that water isn't flowing through the system properly, which has caused it to shut down to prevent overheating.

What to try first

Check that all radiator valves are fully open.Check your boiler pressure gauge to ensure it is between 1 and 1.5 bar, and top it up using the filling loop if it is too low.Restart or reset the boiler to see if the error clears.

Est. cost
£150-350
Parts
Circulating pump, Automatic bypass valve, Flow sensor
Full guide for F23
04
F1 High Engineer

Your boiler is failing to light the internal flame needed to produce heat or hot water.

Est. cost
£120-250
Parts
Ignition electrode, Gas valve, PCB
Full guide for F1
05
F4 High Engineer

Your boiler is failing to light its burner, which means it cannot produce any heating or hot water for your home.

Est. cost
£120-250
Parts
Ignition electrode, Gas valve, Ignition lead
Full guide for F4
06
F2 High Engineer

Your boiler is struggling to clear exhaust gases safely, so it has shut down to prevent any risk of fumes entering your home.

Est. cost
£150-350
Parts
Air pressure switch, Flue fan, Venturi
Full guide for F2

on the Saunier Duval SD Isotwin Condens F35 E

Overheat ThermostatCirculation PumpMain Heat ExchangerCirculating pumpFlow temperature sensor (NTC)Main heat exchanger (flushing/cleaning)

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Saunier Duval shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.

See the full 21-code list for the Saunier Duval SD Isotwin Condens F35 E