The most common Sime Murelle Elite HE 35T System problems

The faults most likely to send a Sime Murelle Elite HE 35T System into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
21 documented codes
6 most common
2 DIY-safe checks
4 engineer needed

The 6 most common faults

01
ALL 02 High DIY-safe

Your boiler has stopped working because the water pressure inside your heating system has dropped too low.

What to try first

Locate the external filling loop (a silver braided hose) underneath the boiler.Open the valves at both ends of the hose to allow water into the system.Watch the pressure gauge on the front of the boiler until the needle reaches the green zone (typically 1.0 to 1.5 bar).Close both valves firmly and ensure the hose is disconnected if required by your specific installation.

Est. cost
£80-120
Parts
Filling loop, Pressure relief valve, Pressure sensor
Full guide for ALL 02
02
ALL 03 High DIY-safe

Your boiler has detected that the water pressure inside your heating system is currently set too high for it to operate safely.

What to try first

Locate a radiator in your home, preferably one upstairs.Using a radiator bleed key, carefully open the bleed valve to let a small amount of water out into a cloth or container.Monitor the pressure gauge on your boiler front panel until it returns to the green zone (typically 1.0 to 1.5 bar), then stop bleeding.

Est. cost
£80-150
Parts
Pressure relief valve, Pressure sensor
Full guide for ALL 03
03
ALL 04 High Engineer

Your boiler is struggling to detect the temperature of the water used for your taps and showers, so it has stopped providing hot water to prevent any potential damage.

Est. cost
£120-220
Parts
DHW NTC sensor, Wiring harness
Full guide for ALL 04
04
ALL 05 High Engineer

Your boiler has detected an issue with the sensor that measures the temperature of the water used for your radiators, meaning it has safely shut itself down to prevent overheating.

Est. cost
£120-220
Parts
Central heating NTC sensor, Wiring harness
Full guide for ALL 05
05
ALL 06 High Engineer

Your boiler has detected an internal safety fault and has stopped operating to prevent further damage.

Est. cost
£150-300
Parts
Main printed circuit board (PCB), Wiring harness, Ignition transformer
Full guide for ALL 06
06
ALL 07 High Engineer

Your boiler has detected that it is dangerously overheating and has automatically shut itself down to prevent damage.

Est. cost
£150-300
Parts
Safety thermostat, Pump, Diverter valve
Full guide for ALL 07

on the Sime Murelle Elite HE 35T System

Filling loopPressure relief valvePressure sensorDHW NTC sensorWiring harnessCentral heating NTC sensor

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Sime shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue