The most common Sime Planet Dewy BFR problems

The faults most likely to send a Sime Planet Dewy BFR into lockout — with plain-English causes, what to check first, estimated repair costs and whether you need a Gas Safe engineer.

This model is discontinued. Parts can be harder to source and expensive. If repair costs are mounting, a new A-rated boiler may be the smarter choice.
5 documented codes
5 most common
2 DIY-safe checks
3 engineer needed

The 5 most common faults

01
Red LED on (solid) High DIY-safe

Your boiler has tried to light but failed to detect a flame, causing it to shut down for safety.

What to try first

Check if other gas appliances, like a hob, are working to confirm gas supply is activeEnsure your gas meter has credit if you use a prepay meterPress and hold the reset button for a few seconds to see if the boiler restarts

Est. cost
£90-250
Parts
Ignition electrode, Flame sensing probe, Gas valve
Full guide for Red LED on (solid)
02
Red LED after flow switch High DIY-safe

Your boiler has stopped working because water isn't moving through the system correctly, causing it to overheat or fail to detect flow.

What to try first

Check that the boiler pressure is between 1.0 and 1.5 bar on the gaugeEnsure all radiator valves and isolation valves under the boiler are fully openTry resetting the boiler by turning the selector switch to the reset position and back

Est. cost
£120-350
Parts
Circulation pump, Water flow switch, Limit thermostat
Full guide for Red LED after flow switch
03
Red LED on (after safety stat) High Engineer

Your boiler has shut down because it grew too hot internally, and for your safety, a permanent lockout has been triggered.

Est. cost
£120-350
Parts
Circulation pump, Safety thermostat (Overheat stat), Main heat exchanger (Cleaning)
Full guide for Red LED on (after safety stat)
04
LED flashing after fan High Engineer

Your boiler has identified a problem with the fan that should be clearing out exhaust fumes, preventing it from starting up safely.

Est. cost
£180-350
Parts
Fan assembly, Fan wiring harness, Main PCB
Full guide for LED flashing after fan
05
Orange LED flashing High Engineer

Your boiler has detected a problem with the internal temperature sensor that controls your central heating, meaning the system cannot accurately monitor the water temperature.

Est. cost
£90-160
Parts
NTC Heating Sensor, Sensor Wiring Harness
Full guide for Orange LED flashing

on the Sime Planet Dewy BFR

Ignition electrodeFlame sensing probeGas valveIgnition leadCirculation pumpWater flow switch

Based on parts cited in our fault code database. Your engineer will confirm what's actually needed after diagnosis.

Call a Gas Safe engineer if…

  • You can smell gas or see signs of a leak
  • The Sime shows an Emergency or High severity code
  • The boiler keeps locking out after repeated resets
  • You've tried the DIY checks and the fault hasn't cleared
  • There's visible water leaking from the boiler
  • The flame is yellow or orange instead of blue