Vaillant F.60 Fault Code
Also written as F60 — same fault.
The Vaillant F.60 fault code means: your boiler has detected an electrical fault with the part that controls the gas supply, meaning it cannot ignite safely for heating or hot water.. It appears on 19 Vaillant models in our database.
Technical description: Gas–valve control + defective | Cause: Short circuit/earth (ground) leak in cable loom to gas valves, gas valve assembly defective (earth/ground leak from coils), electronic control system defective
What causes the Vaillant F.60 fault?
This fault occurs when the boiler's internal computer detects an electrical failure or a 'leak' of electricity within the components that regulate gas flow. The most common reason is that the electromagnetic coils inside the gas valve have worn out or developed a short circuit, preventing the system from opening the valve safely. It can also be caused by damaged wiring or a fault on the main control board itself, which stops the signals from reaching the valve.
Engineer required
This fault requires a Gas Safe registered engineer. Do not attempt gas-related repairs yourself.
Find a Gas Safe engineer
Search the official register for a qualified engineer in your area.
Gas Safe Register →Avoid the next call-out bill
A cover plan would handle faults like F.60: no call-out fees, no surprise bills.
Affiliate links. We may earn a commission at no extra cost to you.
Vaillant models that show the F.60 fault code
Click a model for the full fault code list and model-specific repair notes.
- Atmomax Repair: £200-£450
- ecoMAX Repair: £180-£450
- ecoMAX 613 Repair: £180-£450
- ecoMAX 618 Repair: £180-£450
- ecoMAX 622 Repair: £180-£450
- ecoMAX 635 Repair: £180-£450
- ecoMAX 824E Repair: £180-£450
- ecoMAX 828E Repair: £180-£450
- Ecomax Condensing 600/800 series Repair: £250-450
- ecoMAX System 612 Repair: £180-£450
- ecoTEC plus aquaPLUS Repair: £280-550
- Thermocompact Repair: £280-450
- Turbomax 824/828 Repair: £250-450
- Turbomax Plus Repair: £250-450
- Turbomax Plus 824/828E Repair: £250-£450
- Turbomax Plus 828 Repair: £250-£450
- Turbomax Plus 828 E Repair: £250-£450
- Turbomax Plus VUW 242E Repair: £250-£450
- Turbomax Plus VUW 242EH Repair: £250-£450
Source
Vaillant F.60 fault code information on this page is sourced and cross-checked against the official Vaillant service / installation manuals for each affected model.
- Vaillant ecoMAX manual (PDF)
- Vaillant ecoMAX System 612 manual (PDF)
- Vaillant ecoMAX 824E manual (PDF)
Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 7 July 2026