Vaillant S.96 Fault Code
Also written as S96 — same fault.
The Vaillant S.96 fault code means: your boiler is performing a self-diagnostic check on its internal temperature sensors and has temporarily paused heating until it confirms everything is working correctly.. It appears on 25 Vaillant models in our database.
Technical description: Return temperature sensor self-test: Return sensor test running, heating demands are blocked.
What causes the Vaillant S.96 fault?
This occurs when the boiler's control system notices an unusual discrepancy between the temperature readings of the flow and return pipes. To ensure the heat exchanger doesn't overheat, the boiler pauses operation to run a quick test and verify that the internal sensors are reporting accurate data. It is often triggered by air bubbles trapped in the system or a pump that is beginning to struggle with water circulation.
This can be more frequent in autumn when the heating is turned on for the first time after summer, as air often settles in the pipework during the warmer months.
DIY fix possible
Wait up to 15 minutes for the automated test to completeSwitch the boiler off and back on at the fused spur switch to trigger a restartEnsure all radiator valves are open to allow for proper water circulation
Find a Gas Safe engineer
Search the official register for a qualified engineer in your area.
Gas Safe Register →Vaillant models that show the S.96 fault code
Click a model for the full fault code list and model-specific repair notes.
- Atmomax Repair: £90-180
- Combi Compact 242EB Repair: £90-160
- Combi Compact 282EB Repair: £120-190
- ecoTEC
- ecoTEC exclusive Repair: £0-120
- ecoTEC plus Repair: £0-180
- ecoTEC Plus 615 Repair: £0-180
- ecoTEC Plus 620 Repair: £0-180
- ecoTEC Plus 625 Repair: £0-180
- ecoTEC Plus 630 Repair: £0-180
- ecoTEC Plus 635 Repair: £0-180
- ecoTEC Plus 65 Repair: £0-180
- ecoTEC Plus 826
- ecoTEC Plus 832 Repair: £0-180
- ecoTEC Plus 836 Repair: £0-180
- ecoTEC Plus 840 Repair: £0-180
- ecoTEC Plus 938 Repair: £0-180
- ecoTEC plus Regular Repair: £90-160
- ecoTEC plus System
- ecoTEC Pro Repair: £0-120
- ecoTEC Pro 24 Repair: £0-120
- ecoTEC Pro 28 Repair: £0-120
- ecoTEC Pro 30
- ecoTEC sustain Repair: £0-180
- Home System Repair: £90-180
Source
Vaillant S.96 fault code information on this page is sourced and cross-checked against the official Vaillant service / installation manuals for each affected model.
Reviewed by the BoilerFaultCodes Editorial Team · Last reviewed 27 April 2026