NocommunicationbetweenthePCBandtheuserinterface
Vaillant ecoFIT pure 630 Fault codes & diagnostics
41 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.
The fault code is already on your display
Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →
Severity at a glance
Each cell = one fault code. Hover to identify.Which version do you have?
The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.
| GC number | Appliance (register name) | Produced |
|---|---|---|
| 41-694-07 | ecoFIT pure 630 VU 306/6-3 (H-GB) | 2016–present |
Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.
All 41 documented codes
Tap any card for details
Fault: Flow temperature sensor
Fault: Return temperature sensor
Short circuit: Flow temperature sensor
Short circuit: Return temperature sensor
Short circuit: Cylinder temperature sensor
Short circuit: Domestic hot water cylinder temperature sensor
Safety switch-off: Overheating temperature reached
System water pressure too low (switches off the product)
Safety switch-off: Temperature difference too great (NTC1/NTC2)
Safety switch-off: Temperature rise too fast
Safety switch-off: Flue gas temperature too high
Safety switch-off: Fault in flame detection
Fault: Ignition unsuccessful when starting up
Fault: Flame loss
Fan frost protection function active: Fan speed outside the tolerance values
eBUS fault: Voltage too low
Fault: Gas valve control system
Fault: Gas valve switch-off control
Fault: EEPROM
Fault: Electronics/sensor/analogue-to-digital converter
Fault: Electronics temperature too high
Values sent back by ASIC is incorrect (flame signal)
Fault:Unstableflame(analogueinput)
Invalidproductcode(DSN)
Fault:Flow/returntemperaturesensor
Fault:Deviationinthewaterpressuresensor/returntemperaturesensor
Fault:Waterpressuresensornotconnectedorhasshort-circuited
Fault:Electricalprobleminthewaterpressuresensor
Fault:Pressuresensor
Thesafetycut-outintheprimaryheatexchangerisdefective
Fault:Condensateorsmoke
InterruptiontoDHWoutletsensoratexternalcontroller
Fault:Dryfire
Fault:Flow/returntemperaturesensor
Fault:Temperaturesensor
Fault:Underfloorheatingcontact
Fault:Electrodes
Fault:Gasvalve
Fault:Pump
Short circuit: Cylinder temperature sensor
Avoid the next call-out bill
Monthly cover means no unexpected bills when your boiler breaks down.
Affiliate links. We may earn a commission at no extra cost to you.