No communication between the main PCB and the user interface Electronics defective
Vaillant ecoFIT sustain 830 Fault codes & diagnostics
43 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.
The fault code is already on your display
Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →
Severity at a glance
Each cell = one fault code. Hover to identify.Which version do you have?
The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.
| GC number | Appliance (register name) | Produced |
|---|---|---|
| 47-044-72 | ecoFIT sustain 830 VUW 306/6-3 (H-GB) | 2016–present |
Appliance names and production years are taken from the UK Product Characteristics Database (the SAP/SEDBUK register). Where a GC number is also printed in this model's own manufacturer manual, both sources were checked to agree.
All 43 documented codes
Tap any card for details
Fault: Flow temperature sensor
Fault: Return temperature sensor
Short circuit: Flow temperature sensor
Short circuit: Return temperature sensor
Short circuit: Cylinder temperature sensor
Short circuit: Temperature sensor for the domestic hot water cylinder
Safety shutdown: Overheating temperature reached
Insufficient water pressure in the heating installation
Safety shutdown: Temperature spread too great (NTC1/NTC2)
Safety shutdown: Temperature rise too fast
Safety shutdown: Flue gas temperature too high
Safety shutdown: Fault in flame detection
Fault: Ignition unsuccessful when starting up
Fault: Flame loss
Fan frost protection function active: Fan speed outside the tolerance values
eBUS fault: Voltage too low
Fault: Gas valve assembly control
Fault: Gas valve switch-off control
Fault: EEPROM
Fault: Electronics/sensor/analogue-to-digital converter
Fault: Electronics temperature too high
Values sent back by ASIC is incorrect (flame signal)
Fault
Invalid product code (DSN) Display and PCB replaced at same time and Device Specific Number not reset, wrong or missing output coding resistor
Fault: Flow/return temperature sensor Flow temperature sensor signalling constant value: Flow temperature sensor incorrectly positioned on flow pipe, flow temperature sensor defective
Fault: Deviation in the water pressure sensor/return temperature sensor Flow/return NTC temperature difference too great → flow and/or return temperature sensor defective
Fault: Water pressure sensor not connected or has short-circuited Interruption/short circuit of water pressure sensor, interruption/short circuit to GND in supply pipe to water pressure sensor or water pressure sensor defective
Fault: Electrical problem in the water pressure sensor Line to water pressure sensor has a short circuit to 5V/24V or internal fault in the water pressure sensor
Fault: Pressure sensor Pressure switch defective
The safety cut-out in the primary heat exchanger is defective Safety cut-out feedback does not match the gas valve assembly feedback
Fault: Condensate or smoke No response, flue non-return flap defective
Interruption to DHW outlet sensor at external control UK link box is connected, but domestic hot water NTC not bridged
Fault: Dry fire When the burner starts, the temperature change registered at the flow or return temperature sensor is non-existent or too small: Insufficient water in the product, the flow or return temperature sensor is not in the correct position on the pipe
Fault: Flow/return temperature sensor Values not consistent, difference < -6K Flow and return temperature sensors signalling implausible values: Flow and return temperature sensors have been inverted, flow and return temperature sensors have not been correctly installed
Fault: Temperature sensor The flow and/or return temperature sensors have been installed on the same pipe/incorrect pipe Temperaturesensor not connected or is connected incorrectly
Fault: Underfloor heating contact Underfloor heating contact open, sensor disconnected or defective
Fault: Electrodes Electrodes not connected or they are connected incorrectly, short circuit in the cable harness
Fault: Gas valve assembly Gas valve assembly not connected or it is connected incorrectly, short circuit in the cable harness
Fault: Pump Pump not connected or it is connected incorrectly, incorrect pump connected, short circuit in the cable harness
Main PCB self-test failed Main PCB defective
Heating mode active
Hot water generation active
Avoid the next call-out bill
Monthly cover means no unexpected bills when your boiler breaks down.
Affiliate links. We may earn a commission at no extra cost to you.