Vaillant ecoTEC Plus 610 Fault codes & diagnostics

34 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

System Natural Gas 10 kW 2018-present
GC Number 41-044-76
Download the Vaillant ecoTEC Plus 610 manual The official installation & service manual (PDF) — the exact document these fault codes were verified against. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
6 Emergency 26 High 2 Medium

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
41-044-76 ecoTEC plus 435 VU 356/6-5 OVZ (H-GB) 2018–present

All 34 documented codes

Tap any card for details

Connection

Your boiler has lost the ability for its main control brain to talk to the display screen, meaning it cannot receive commands or function correctly.

High Engineer only £200-450

Parts commonly replaced

  • Main PCB
  • User Interface Display Module
  • Wiring Harness

Related codes

F.00

Your boiler has lost the signal from one of its internal temperature sensors, so it has shut down to prevent overheating.

High Engineer only £120-200

Parts commonly replaced

  • NTC temperature sensor
  • Wiring harness

Related codes

F.01

Your boiler has lost the signal from a temperature sensor that monitors the water returning to the system, causing it to stop heating as a safety precaution.

High Engineer only £120-220

Parts commonly replaced

  • Return NTC sensor
  • Wiring harness

Related codes

F.10

Your boiler has detected an electrical fault in a temperature sensor, which is preventing it from safely monitoring the water heat levels and stopping it from operating.

High Engineer only £120-220

Parts commonly replaced

  • Flow temperature sensor (NTC)
  • Wiring harness

Related codes

F.11

Your boiler's temperature-monitoring system has detected a faulty signal, likely due to a loose wire or a broken sensor, preventing it from heating your home safely.

High Engineer only £120-200

Parts commonly replaced

  • Return NTC sensor
  • Wiring harness

Related codes

F.13

Your boiler is struggling to read the water temperature in your hot water tank due to a loose wire or a faulty sensor, so it has shut down the heating to prevent issues.

High Engineer only £120-220

Parts commonly replaced

  • NTC Temperature Sensor
  • Wiring Harness

Related codes

F.20

Your boiler has detected that it is running too hot and has automatically shut itself down to prevent damage.

High Engineer only £150-300

Parts commonly replaced

  • NTC Temperature Sensor
  • Ignition Lead
  • Main PCB

Related codes

F.23

Your boiler has detected that it is heating up much faster than it can move that heat away, which usually means the water pump is stuck or there is an air pocket trapped inside the system.

High Engineer only £120-250

Parts commonly replaced

  • Central heating pump
  • NTC thermistor sensors
  • System bypass valve

Related codes

F.24

Your boiler has detected that it is overheating very quickly because water is not flowing through the system as it should.

High Engineer only £150-300

Parts commonly replaced

  • Central heating pump
  • System pressure sensor
  • System water filter
F.25

Your boiler has detected that the exhaust gases are becoming dangerously hot, or a safety sensor connection has been disconnected, so it has shut down to prevent damage.

Emergency Engineer only £150-300

Parts commonly replaced

  • Flue gas thermostat
  • Wiring harness
  • Main PCB

Related codes

Showing 11–20 of 34
F.27

Your boiler has detected an issue with its flame monitoring system and has automatically shut down to ensure your safety.

Emergency Engineer only £150-350

Parts commonly replaced

  • Printed circuit board
  • Gas valve
  • Wiring harness

Related codes

F.28

Your boiler is failing to ignite because it cannot detect a flame or receive the necessary gas supply to start up.

High Engineer only £150-350

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • PCB
  • Ignition lead

Related codes

F.29

Your boiler has failed to stay ignited, which means it has safely shut itself down because it cannot keep a steady flame.

High Engineer only £150-350

Parts commonly replaced

  • Ignition lead
  • Ignition electrode
  • Gas valve
  • PCB

Related codes

F.32

Your boiler has detected that the internal fan responsible for moving air is not spinning at the correct speed or is being blocked, preventing the boiler from firing up safely.

High Engineer only £180-350

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • Main PCB

Related codes

F.49

Your boiler's communication system is experiencing an electrical connection issue that is preventing it from sending instructions correctly.

High Engineer only £120-250

Parts commonly replaced

  • eBUS PCB
  • Wiring harness
  • External controls integration module

Related codes

F.61

Your boiler has detected an electrical fault in the system that controls the gas supply, meaning it has safely shut itself down to prevent any unsafe operation.

Emergency Engineer only £200-400

Parts commonly replaced

  • Gas valve
  • Main PCB

Related codes

F.62

Your boiler has detected an issue with its internal components responsible for safely stopping the gas flow, meaning it cannot shut down correctly.

Emergency Engineer only £250-450

Parts commonly replaced

  • Gas valve
  • Main PCB

Related codes

F.63

Your boiler's main computer control panel has suffered a critical internal memory failure and can no longer process instructions to run your heating system.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB (Printed Circuit Board)

Related codes

F.64

Your boiler's computer is misreading temperature information from sensors, meaning it cannot safely control your heating or hot water.

High Engineer only £150-300

Parts commonly replaced

  • NTC Temperature Sensor
  • Main PCB

Related codes

F.65

Your boiler's main control unit is overheating, which has caused it to shut down for safety to prevent permanent damage.

High Engineer only £250-500

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

Showing 21–30 of 34
F.67

Your boiler has detected an internal electronics error that prevents it from safely confirming if the flame is burning correctly, so it has shut down to protect your home.

High Engineer only £250-450

Parts commonly replaced

  • Main printed circuit board (PCB)
  • Flame rectification probe

Related codes

F.68

Your boiler is struggling to keep its internal flame lit or detect it properly, which is preventing it from heating your home safely.

High Engineer only £150-350

Parts commonly replaced

  • Ionisation electrode
  • Gas valve
  • Flame rectification lead

Related codes

F.70

Your boiler’s internal computer has lost its identification settings, usually because a part was replaced without being properly programmed to match your specific system.

High Engineer only £100-200

Parts commonly replaced

  • Main PCB
  • Coding resistor

Related codes

F.71

Your boiler is struggling to accurately measure the temperature of the water flowing through the system, causing the heating to stop as a safety precaution.

High Engineer only £150-250

Parts commonly replaced

  • Flow temperature sensor
  • NTC thermistor

Related codes

F.72

Your boiler has detected that the water temperature is not moving through the system as expected, which prevents it from working reliably.

High Engineer only £150-300

Parts commonly replaced

  • NTC Temperature Sensor
  • Water Pressure Sensor
  • Main PCB
F.77

Your boiler has detected a potential blockage or mechanical issue with the system that manages exhaust gases, which has triggered a safety shutdown to prevent harmful gases from entering your home.

Emergency Engineer only £150-300

Parts commonly replaced

  • Flue non-return flap
  • Condensate trap assembly
  • PCB
F.78

Your boiler is having trouble communicating with the external controls or hot water system, which is preventing it from heating your water correctly.

High Engineer only £120-250

Parts commonly replaced

  • VR65 or VR66 Wiring Centre
  • Hot Water Cylinder NTC Sensor
  • Wiring loom
F.83

Your boiler is not detecting enough water circulating inside the system to safely turn on the burner.

High Engineer only £120-250

Parts commonly replaced

  • Flow temperature sensor
  • Return temperature sensor
  • System pump
F.84

Your boiler is confused because internal temperature sensors are either misread or have been incorrectly fitted, preventing the system from heating your home safely.

High Engineer only £150-£250

Parts commonly replaced

  • NTC temperature sensor
  • Wiring harness
  • PCB

Related codes

F.85

Your boiler is confused because its temperature probes are detecting heat in the wrong places, likely due to a wiring issue or the sensors being moved.

High Engineer only £120-220

Parts commonly replaced

  • NTC temperature sensor
  • Wiring harness

Related codes

Showing 31–34 of 34
F.86

Your boiler has detected that a safety sensor meant to prevent underfloor heating pipes from overheating is not sending a signal or is disconnected.

Medium Engineer only £120-250

Parts commonly replaced

  • Underfloor heating contact sensor
  • Wiring harness
  • Connection plug

Related codes

F.87

Your boiler has lost the internal connection needed to detect the flame, so it has safely shut down to prevent any gas buildup.

High Engineer only £120-250

Parts commonly replaced

  • Ignition lead
  • Ignition electrode
  • Wiring harness

Related codes

F.88

Your boiler has lost its connection to the component that controls the gas flow, meaning it cannot ignite safely to provide heating or hot water.

Emergency Engineer only £180-350

Parts commonly replaced

  • Gas valve
  • Wiring harness
  • Main PCB

Related codes

F.91

Your boiler is struggling to read the temperature of your hot water cylinder because there is a faulty connection or wiring issue with the sensor responsible for monitoring it.

Medium Engineer only £120-200

Parts commonly replaced

  • Cylinder NTC sensor
  • Wiring harness

38 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.

d.02 Diagnostic Your boiler is currently in a mandatory waiting period to prevent it from overheating after it has just finished a heating cycle. d.10 Diagnostic Your boiler is signalling that the pump responsible for moving water through your heating system is not responding correctly. d.11 Diagnostic Your boiler is signalling that the pump responsible for moving water through your heating system is not responding correctly. P.01 Diagnostic Your boiler is currently performing a brief automatic self-test during its initial power-up sequence and is not actually reporting a fault. S.0 Status Your boiler is currently in standby mode because it has not been asked to provide any heating or hot water at this moment. S.01 Status Your boiler is currently preparing to ignite by running its internal fan, which is a normal part of the start-up sequence. S.02 Status Your boiler is simply preparing to heat your home by circulating water through the pipes before it fires up the burner. S.03 Status Your boiler is currently in the process of starting up its flame to begin heating your home. S.04 Status Your boiler is operating normally and is currently in the active process of heating your radiators. S.05 Status Your boiler is currently performing a normal cooling-down process after your heating or hot water has been running. S.06 Status Your boiler is simply performing a routine safety process where the internal fan runs for a short time after the heating has turned off to clear any leftover gases. S.07 Status Your boiler is simply finishing its cooling cycle after the heating or hot water has turned off, which is a perfectly normal part of its operation. S.08 Status Your boiler is currently taking a short, scheduled break after finishing its last heating cycle and will start up again automatically when needed. S.20 Status Your boiler is currently operating normally as it is in the process of heating water for your taps or radiators. S.21 Status Your boiler is currently just running its internal fan to prepare for heating or hot water, and this is a normal part of the startup sequence. S.22 Status Your boiler is simply performing a routine safety check by circulating water before it fires up, so there is nothing to worry about. S.23 Status Your boiler is currently in the process of starting up to heat your water or radiators, which is a completely normal part of its standard operating cycle. S.24 Status Your boiler is currently operating normally as it heats water for your taps and shower. S.25 Status Your boiler is simply finishing its cooling cycle after being used, which is a normal part of its automatic shutdown process. S.26 Status Your boiler is currently cooling down its internal components after finishing a hot water task, which is a normal part of its operating cycle. S.27 Status Your boiler is simply finishing a cooling-down cycle after providing hot water and is operating exactly as it should. S.28 Status Your boiler is temporarily pausing its heating process to wait for the water temperature to settle, which is a normal part of its operation. S.30 Status Your boiler is perfectly healthy, but it is currently waiting for a signal from your thermostat to tell it that your home needs more heat. S.31 Status Your boiler is perfectly healthy and is simply waiting for a signal from your thermostat or timer to start heating your home. S.32 Status Your boiler's fan is struggling to spin at the correct speed to vent exhaust gases safely, causing the system to pause until the speed stabilises. S.34 Status Your boiler has detected very cold temperatures and has briefly turned itself on to stop the internal pipes from freezing. S.39 Status Your boiler has detected that the external safety switch for your underfloor heating system is currently open or disconnected, preventing the system from running. S.42 Status Your boiler is temporarily waiting because it has detected that the internal safety flap in the flue system is closed, preventing the unit from starting its ignition cycle. S.46 Status Your boiler is temporarily running at a very low power level to keep its internal components from freezing during cold weather. S.53 Status Your boiler has temporarily stopped because it cannot circulate water efficiently, likely due to low pressure or an airlock in your heating system. S.54 Status Your boiler is temporarily pausing because it has detected that the water pressure or the flow of water inside your heating system is not moving correctly. S.88 Status Your boiler is currently running a routine self-clearing cycle to remove air from the system and is not actually experiencing a fault. S.91 Diagnostic Your boiler has been accidentally set to a demonstration mode used in showrooms, which prevents it from heating your home or water. S.96 Status Your boiler is currently performing a brief automatic self-check on its internal sensors, which has temporarily paused your heating. S.98 Status Your boiler is currently performing an automatic system check and has temporarily paused heating to ensure it is operating safely. S.99 Status Your boiler is currently performing a brief, routine internal status check and should resume normal operation automatically once the cycle completes. S.108 Status Your boiler is currently running a routine internal safety cycle to clear out any leftover gases before starting up. S.109 Status Your boiler has entered a temporary sleep mode and is currently not heating your home or water.

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →