Vaillant ecoTEC Plus 630 Fault codes & diagnostics

30 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

System Natural Gas 30 kW 2005-present
GC Numbers 41-044-6441-044-8341-694-2541-694-2641-694-4947-044-6741-044-6741-044-84
Download the Vaillant ecoTEC Plus 630 manual The official installation & service manual (PDF) — the exact document these fault codes were verified against. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
1 Emergency 28 High 1 Medium

Which version do you have?

The GC number on your boiler's data badge identifies the exact appliance and production years, as recorded in the UK Product Characteristics Database.

GC number Appliance (register name) Produced
41-044-64 ecoTEC plus 630 VU GB 306/5-5 2012–2015
41-044-83 ecoTEC plus 630 H system A VU GB 306/5-5 A 2015–2017
41-694-25 ecoTEC plus 630 VU 306/5-5 (H-GB) R6 2017–present
41-694-26 ecoTEC plus 630 VU 306/5-5 (P-GB) R6 2017–present
41-694-49 ecoTEC plus 630 VU 30CS/1-5 (N-GB) 2023–present
47-044-67 ecoTEC plus 630 VU GB 306/5-5 2005–2015
41-044-84 ecoTEC plus 630 LPG system A VU GB 306/5-5 A R4 2015–2017

All 30 documented codes

Tap any card for details

con

Your boiler's control panel and its internal computer are not talking to each other, meaning the unit cannot receive instructions to provide heat or hot water.

High Engineer only £180-450

Parts commonly replaced

  • Main PCB
  • Display Interface Module
  • Wiring harness

Related codes

F.0

Your boiler has stopped working because it cannot accurately measure the temperature of the water leaving the unit due to a sensor or wiring connection fault.

High Engineer only £100-£220

Parts commonly replaced

  • Flow NTC Thermistor
  • NTC Wiring Harness
  • Main PCB

Related codes

F.1

Your boiler has stopped working because it cannot accurately measure the temperature of the water returning to the unit due to a faulty sensor or wiring.

High Engineer only £100-£220

Parts commonly replaced

  • Return NTC thermistor
  • NTC wiring harness
  • Main PCB

Related codes

F.10

Your boiler has detected an electrical fault with the internal sensor that monitors the water temperature leaving the unit, causing it to shut down for safety.

High Engineer only £90-160

Parts commonly replaced

  • NTC Flow Temperature Sensor
  • Wiring harness/connector
  • PCB

Related codes

F.11

Your boiler has stopped working because it thinks the water returning to the unit is much hotter than it actually is, causing it to shut down for safety.

High Engineer only £100-£180

Parts commonly replaced

  • Return temperature sensor (NTC thermistor)
  • Internal wiring loom
  • Main PCB

Related codes

F.13

Your boiler has detected an electrical fault with the sensor that monitors your hot water tank, meaning it cannot accurately tell if your water is hot enough.

Medium Engineer only £90-160

Parts commonly replaced

  • Domestic Hot Water Cylinder NTC Sensor
  • Wiring Harness

Related codes

F.20

Your boiler has switched itself off because it has reached an unsafe temperature and needs to cool down.

High DIY-safe £100-280

What to check first

  1. Ensure all radiator valves are fully open to allow water to flow.
  2. Check the boiler pressure gauge and top up to 1.5 bar if it is too low.
  3. Press the 'Flame' or 'Reset' button and hold for one second to restart the system.

Parts commonly replaced

  • Circulation Pump
  • Overheat Thermostat
  • Main Heat Exchanger (Flushing)

Related codes

F.22

Your boiler has stopped working because the water pressure inside the system has dropped too low to operate safely.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop (usually two braided silver hoses or blue levers) underneath the boiler.
  2. Slowly open both valves until you hear water flowing and the pressure gauge reaches between 1.0 and 1.5 bar.
  3. Close both valves tightly and restart the boiler to clear the fault code.

Parts commonly replaced

  • Filling loop valves
  • Pressure sensor
  • Expansion vessel

Related codes

F.23

Your boiler has shut down because there is a significant difference between the water temperature leaving the boiler and the temperature returning to it, usually caused by a circulation problem.

High DIY-safe £100-£350

What to check first

  1. Ensure all radiator valves (TRVs) are fully open
  2. Check that the boiler pressure is between 1.0 and 1.5 bar
  3. Bleed your radiators to remove any trapped air

Parts commonly replaced

  • Circulation pump
  • NTC thermistor (temperature sensor)
  • Magnetic filter (cleaning)

Related codes

F.24

Your boiler has shut down because the internal water temperature is heating up much faster than it can be circulated away, usually meaning the water is stuck or the pump is struggling.

High DIY-safe £150-£350

What to check first

  1. Check that your boiler pressure is between 1.0 and 1.5 bar on the digital display.
  2. Ensure at least two or three radiator valves are turned fully open to allow water flow.
  3. Try resetting the boiler by pressing the flame symbol button to see if the fault clears.

Parts commonly replaced

  • Circulation pump
  • Flow and return thermistors
  • Main heat exchanger (flushing)

Related codes

Showing 11–20 of 30
F.27

Your boiler has sensed a flame when there shouldn't be one, so it has shut down as a safety precaution to prevent damage.

High Engineer only £150-350

Parts commonly replaced

  • Ionisation electrode
  • Ignition lead
  • Gas valve
  • Printed Circuit Board (PCB)

Related codes

F.28

Your boiler is trying to light itself to provide heat, but it is failing to create a flame, likely because it is not getting enough gas or the spark isn't catching.

High DIY-safe £100-350

What to check first

  1. Check that your gas emergency control valve is open and any prepay meters have credit.
  2. Verify if other gas appliances in your home, like a hob, are working correctly.
  3. If it is freezing outside, check if your condensate pipe (the plastic pipe leading outside) is frozen and thaw it with warm water.
  4. Press the Reset button (the flame symbol with a cross) for one second.

Parts commonly replaced

  • Ignition Electrode
  • Gas Valve
  • Spark Lead
  • Printed Circuit Board (PCB)

Related codes

F.29

Your boiler was working but the flame went out and it cannot manage to light itself back up.

High DIY-safe £100-£350

What to check first

  1. Check if other gas appliances (like a hob) are working to ensure gas is reaching the property
  2. Check if your gas meter has credit and the isolation valve is open
  3. Press the 'Reset' button (indicated by a flame with a line through it) for three seconds

Parts commonly replaced

  • Ignition Electrode
  • Gas Valve
  • Spark Lead

Related codes

F.32

Your boiler's fan is unable to spin at the correct speed, which prevents the boiler from safely clearing exhaust fumes and starting the ignition process.

High Engineer only £250-£450

Parts commonly replaced

  • Combustion Fan
  • PCB (Main Control Board)
  • Wiring harness

Related codes

F.49

Your boiler has lost its ability to communicate with its external controls, such as your thermostat, due to an electrical glitch in the internal data wiring.

High Engineer only £100-250

Parts commonly replaced

  • eBUS cable
  • External controls receiver
  • PCB (Printed Circuit Board)

Related codes

F.61

Your boiler is unable to correctly control the flow of gas, causing it to shut down for safety purposes.

High Engineer only £250-£550

Parts commonly replaced

  • Gas valve
  • Printed Circuit Board (PCB)
  • Wiring harness

Related codes

F.62

Your boiler has detected that the gas valve is not closing as quickly as it should, preventing the unit from shutting down the burner safely.

Emergency Engineer only £250-£550

Parts commonly replaced

  • Gas Valve
  • Printed Circuit Board (PCB)

Related codes

F.64

Your boiler has detected an internal communication error between its electrical sensors and the main control board, causing it to shut down for safety.

High Engineer only £180-450

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • NTC Temperature Sensors
  • Wiring Loom

Related codes

F.65

Your boiler's internal control board has become too hot and has shut down the system to prevent damage.

High Engineer only £250-450

Parts commonly replaced

  • Main PCB (Printed Circuit Board)
  • Display PCB

Related codes

Showing 21–30 of 30
F.67

Your boiler's electronic control board has detected a confusing signal from the flame sensor, causing the system to shut down for safety.

High Engineer only £280-£450

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Electrode / Flame Sensor

Related codes

F.70

Your boiler’s control board has lost its identity settings, meaning the internal computer no longer knows which specific model it is supposed to be operating.

High Engineer only £100-£350

Parts commonly replaced

  • Main Printed Circuit Board (PCB)
  • User Interface Display Board

Related codes

F.71

Your boiler is struggling to accurately measure the water temperature leaving the unit, usually because a sensor has failed or become disconnected.

High Engineer only £90-160

Parts commonly replaced

  • Flow temperature sensor (NTC)
  • Return temperature sensor (NTC)
  • Wiring harness

Related codes

F.72

Your boiler has detected that the sensors measuring water temperature going in and out are giving conflicting readings, so it has shut down as a safety precaution.

High Engineer only £120-220

Parts commonly replaced

  • Flow NTC sensor
  • Return NTC sensor
  • Sensor wiring harness

Related codes

F.75

Your boiler is unable to sense water moving or pressure building when it tries to start up, which has caused it to shut down for safety.

High DIY-safe £180-350

What to check first

  1. Check the pressure gauge and ensure it is between 1.0 and 1.5 bar
  2. If pressure is too low, use the filling loop to top it up
  3. Reset the boiler to see if the fault clears

Parts commonly replaced

  • Water Pressure Sensor
  • Circulation Pump
  • Expansion Vessel

Related codes

F.76

Your boiler's safety sensor has detected that the main heating component is getting too hot, so the system has shut itself down to prevent damage.

High Engineer only £450-900

Parts commonly replaced

  • Thermal fuse
  • Heat exchanger
  • Wire harness

Related codes

F.77

Your boiler is struggling to push waste gases out through the flue or is unable to clear internal condensation water properly.

High Engineer only £120-350

Parts commonly replaced

  • Condensate pump
  • Flue gas non-return flap
  • Wiring harness

Related codes

F.78

Your boiler is having trouble communicating with an external hot water control component, meaning it doesn't know the temperature of the water heading to your taps.

High Engineer only £90-180

Parts commonly replaced

  • DHW NTC Sensor
  • External Link Box
  • Wiring harness

Related codes

F22

Your boiler has stopped working because the water pressure is too low for it to operate safely.

High DIY-safe £0-120

What to check first

  1. Locate the filling loop handles (usually two blue or black taps) underneath the boiler.
  2. Slowly turn both handles 90 degrees to allow water into the system while watching the pressure gauge.
  3. Close both handles fully once the pressure reaches between 1.0 and 1.5 bar.

Parts commonly replaced

  • Filling loop
  • Expansion vessel
  • Pressure sensor
F70

Your boiler's computer brains are not talking to each other correctly because a security code needs to be re-entered after a repair.

High Engineer only £80-120

Parts commonly replaced

  • Main PCB
  • User Interface display board

66 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.

d.10 Diagnostic Your boiler is simply reporting the current activity status of its internal water pump to let you know if it is turned on or off. d.11 Diagnostic Your boiler is simply reporting that a secondary pump, responsible for circulating water through your heating system, is currently not running. d.13 Diagnostic Your boiler is simply reporting that the internal pump responsible for moving hot water is currently resting or has just switched on. d.17 Diagnostic Your boiler is currently configured to monitor the temperature of water returning from your heating system rather than the water leaving it, which is a specific setting typically used for underfloor heating systems. d.18 Diagnostic Your boiler is simply showing its current pump setting status rather than a fault; it indicates whether the pump is running constantly or only when needed. d.19 Diagnostic This code is simply an information status display showing how your boiler's internal water pump is currently being told to operate, rather than an error or a fault with your heating system. d.20 Diagnostic This code is not actually an error; it is a status message showing the current setting for your maximum hot water temperature. d.22 Diagnostic Your boiler is simply reporting that it is currently not being asked to produce any hot water. d.23 Diagnostic Your boiler is simply reporting that it is currently set to standby mode and is not being asked to provide heating or hot water. d.25 Diagnostic Your boiler is simply indicating that the 'warm start' or cylinder heating feature requested by your thermostat is currently turned off. d.27 Diagnostic This code is not actually an error, but a display setting that shows which external device or auxiliary pump is currently connected to your boiler's secondary circuit. d.28 Diagnostic This code is not actually an error, but a display setting that shows which external device your boiler is currently controlling. d.33 Diagnostic Your boiler is displaying the current operating speed of the fan, which is a normal status message rather than a breakdown. d.34 Diagnostic This code is simply showing you the current speed of your boiler's internal cooling fan and is not a warning of a fault. d.35 Diagnostic Your boiler is currently reporting the status of the valve that switches your water flow between heating your home and heating your hot water tap. d.36 Diagnostic This code is simply showing you a live readout of how much hot water is currently flowing through your boiler and is not an error message. d.40 Diagnostic This code is not a fault; it is simply showing you the current temperature of the water flowing through your heating system. d.41 Diagnostic Your boiler is simply displaying the current temperature reading of the water returning to it from your radiators; this is an information code rather than a fault. d.47 Diagnostic Your boiler is simply displaying the current temperature reading from an external weather sensor connected to your system. d.50 Diagnostic Your boiler is displaying a diagnostic setting for its internal air fan rather than a breakdown error, but it may indicate an issue with the fan's operation or the circuit board settings. d.51 Diagnostic Your boiler is currently recalibrating its internal fan settings and is not reporting a failure; it is performing a routine adjustment rather than displaying an active heating breakdown. d.58 Diagnostic Your boiler is currently checking its settings for solar-heated water to ensure it meets safety standards for preventing bacteria growth. d.60 Diagnostic Your boiler has detected that it is getting too hot and has switched itself off multiple times to prevent damage. d.61 Diagnostic Your boiler has failed to light several times and is currently recording these failed attempts rather than performing an action. d.64 Diagnostic This code is simply an information display showing how long your boiler takes to light the flame on average, rather than an error or a fault with your heating system. d.65 Diagnostic This code is not an error, but rather a status display showing how long the boiler took to light its flame during the last ignition attempt. d.67 Diagnostic Your boiler is currently in a mandatory waiting period, purposely resting to prevent it from cycling on and off too frequently. d.68 Diagnostic Your boiler is struggling to light itself on the first try and is keeping a record of these failed attempts. d.69 Diagnostic Your boiler has failed to light the flame after two attempts and is currently tracking how many times this has happened. d.70 Diagnostic Your boiler is currently monitoring or testing the internal valve that decides whether to send hot water to your radiators or your taps. P.0 Diagnostic Your boiler is currently running a self-cleaning routine to remove trapped air bubbles from the system. P.1 Diagnostic Your boiler is simply running a routine internal test to check it can operate at its maximum power level after starting up. P.2 Diagnostic Your boiler is currently running a background self-test to check it can operate safely at its lowest power setting. P.3 Diagnostic Your boiler is undergoing a temporary calibration process where it checks its heating settings; it is not a fault, but a normal status message. P.4 Diagnostic Your boiler is currently running a safety program to remove trapped air from the internal pipes and heat exchanger. P.5 Diagnostic Your boiler is running a specialized internal test to ensure its safety sensor correctly shuts the system down if it gets too hot. P.6 Diagnostic Your boiler is currently running a self-diagnostic test to check the water pressure and fill level as it prepares to start up. S.0 Status Your boiler is working perfectly fine and is simply in standby mode because your thermostat is not currently asking for the heating to be turned on. S.1 Status Your boiler is preparing to ignite but is stuck at the stage where the internal fan is spinning up to clear the combustion chamber. S.2 Status Your boiler is currently moving water through the system after a heating or hot water cycle to cool down the internal components safely. S.3 Status Your boiler is currently trying to light the flame to start provide heating or hot water, and this is a normal status message rather than a permanent error. S.4 Status Your boiler is operating normally and is currently in the process of starting up the burner to provide heat or hot water. S.5 Status Your boiler is pausing during its startup sequence while it waits for a signal that the fire has safely lit. S.6 Status Your boiler's fan is continuing to run for longer than expected after the heating or hot water has finished. S.7 Status Your boiler is briefly keeping the internal pump running to safely circulate and dissipate leftover heat after you have finished using your heating or hot water. S.8 Status Your boiler has reached the correct temperature and is taking a short, planned break to prevent it from switching on and off too frequently. S.20 Status Your boiler is not broken; it is simply letting you know that it has received a request to provide hot water and is currently preparing to deliver it. S.21 Status Your boiler is briefly checking its fan and clearing the system before it starts heating your hot water. S.22 Status Your boiler is not broken; it is simply performing a routine preparation step to ensure everything is ready before it begins heating your water. S.23 Status Your boiler is currently preparing the burner to provide hot water, which is a normal part of its operation. S.24 Status Your boiler is working normally and is currently heating up your hot water. S.25 Status Your boiler is briefly cooling itself down after providing hot water and will resume normal operation in a few moments. S.26 Status Your boiler is simply running its internal fan for a short period to cool down after you have finished using hot water. S.27 Status Your boiler is briefly running the internal pump after providing hot water to help cool down the internal components. S.28 Status Your boiler has temporarily stopped the burner because it has reached the required temperature for hot water and is taking a short break to prevent overheating. S.30 Status Your boiler is working fine, but your external room thermostat or timer is telling it not to turn the heating on right now. S.31 Status Your boiler is working correctly but is currently ignoring heating requests because it is either set to summer mode or is waiting for a command from your external thermostat. S.32 Status Your boiler is struggling to start because the internal fan is not spinning at the correct speed required for a safe ignition. S.34 Status Your boiler has sensed the temperature is very cold and is automatically running to prevent the internal pipes from freezing. S.36 Status Your boiler is working fine, but your external thermostat or heating controls aren't telling it to turn on. S.41 Status Your boiler has detected that there is too much water in the system, which puts extra stress on the pipes and components. S.42 Status Your boiler has detected that a safety flap in the flue pipe is stuck closed, preventing exhaust gases from escaping. S.53 Status Your boiler has temporarily stopped working because it has detected that water is the not moving through the system quickly enough to safely carry heat away. S.54 Status Your boiler has paused because it detects that water is not circulating quickly enough, often due to low pressure or an air pocket. S.96 Status Your boiler is temporarily paused because it is running a self-diagnostic check on its internal temperature sensors to ensure they are working correctly. S.98 Status Your boiler is temporarily paused because it has detected a potential issue with its internal sensors while performing a self-test.

Avoid the next call-out bill

Monthly cover means no unexpected bills when your boiler breaks down.

Approved partner
Domestic Appliance Guard
Unlimited call-outs, 24/7 helpline, no price-hike promise
Get a quote →

Affiliate links. We may earn a commission at no extra cost to you.