Vaillant ecoTEC plus 831 VUW GB 316/3-5 Fault codes & diagnostics

27 fault codes with plain-English explanations, severity ratings, DIY guidance, and repair cost estimates.

Combi Natural Gas 2004-about 2006 Discontinued
GC Number 47-044-32
Download the Vaillant ecoTEC plus 831 VUW GB 316/3-5 manualThe official installation and service manual (PDF), the document these fault codes were read from. PDF

The fault code is already on your display

Note it down before pressing reset — resetting clears the code immediately. How to read fault codes →

Severity at a glance

Each cell = one fault code. Hover to identify.
4 Emergency 19 High 3 Medium 1 Low

All 27 documented codes

Tap any card for details

F.00

Your boiler has temporarily stopped working because it cannot properly read the temperature of the water flowing through its system.

High Engineer only £90-£180

Parts commonly replaced

  • Flow NTC temperature sensor
  • Wiring harness

Related codes

F.01

Your boiler has temporarily stopped working because it cannot properly read the temperature of the water returning from your radiators.

High Engineer only £90-180

Parts commonly replaced

  • Return temperature sensor (NTC)
  • Wiring harness

Related codes

F.02

Your boiler has detected a temperature reading that is unusually low, though this specific sensor fault usually applies to combination boilers rather than your system boiler model.

Low Engineer only £90-180

Parts commonly replaced

  • NTC Temperature Sensor
  • Wiring Harness

Related codes

F.10

Your boiler has stopped working because a temperature sensor on the main water pipe has developed an electrical fault.

High Engineer only £90-180

Parts commonly replaced

  • Flow NTC temperature sensor
  • Wiring harness

Related codes

F.11

Your boiler has detected an electrical fault with one of its internal temperature sensors, which stops it from working safely.

High Engineer only £120-200

Parts commonly replaced

  • Return NTC thermistor
  • Wiring harness

Related codes

F.13

Your boiler has detected a faulty connection or wiring issue with the hot water temperature sensor inside your water cylinder.

Medium Engineer only £90-180

Parts commonly replaced

  • Hot water cylinder sensor
  • Sensor wiring harness

Related codes

F.20

Your boiler has temporarily shut down because the internal temperature got too hot, which is a built-in safety feature to prevent damage.

High Engineer only £90-250

Parts commonly replaced

  • NTC temperature sensors
  • Circulation pump
  • Automatic bypass valve
  • Heat exchanger

Related codes

F.22

Your boiler has temporarily stopped working because the water pressure inside your heating system has dropped too low.

High DIY-safe

What to check first

  1. Locate the filling loop hoses underneath your boiler or check your integrated filling system.
  2. Open the valves slowly to let mains water into the heating system until the pressure gauge rises to between 1.0 and 1.5 bar.
  3. Close the valves firmly and press the reset button on your boiler.

Parts commonly replaced

  • Pressure sensor
  • Expansion vessel
  • Manual filling loop

Related codes

F.23

Your boiler has temporarily stopped working because there is either too little water inside or the water cannot circulate properly.

High DIY-safe £90-250

What to check first

  1. Check your system pressure gauge to ensure it is between 1 and 1.5 bar.
  2. If the pressure is too low, use your filling loop to top up the system.
  3. Bleed your radiators to remove any trapped air that might be blocking water flow.

Parts commonly replaced

  • Central heating pump
  • Flow and return temperature sensors
  • Automatic air vent

Related codes

F.24

Your boiler is locking out because the water inside is heating up much too quickly, usually due to low water pressure or a blocked circulation path.

High DIY-safe £150-300

What to check first

  1. Check your boiler's pressure gauge to ensure it is between 1 and 1.5 bars.
  2. Use the filling loop to top up the system pressure if it has dropped below 1 bar.
  3. Reset the boiler using the reset button to see if normal operation resumes.

Parts commonly replaced

  • Circulation pump
  • Flow sensor
  • Automatic air vent

Related codes

Showing 11–20 of 27
F.27

Your boiler has detected a false flame signal inside, meaning it thinks a fire is burning when the gas valve is actually closed.

High Engineer only £150-300

Parts commonly replaced

  • Printed Circuit Board (PCB)
  • Electrodes
  • Gas Valve

Related codes

F.28

Your boiler is trying to start up, but it is failing to ignite the gas safely.

High Engineer only £150-350

Parts commonly replaced

  • Ignition electrode
  • Gas valve
  • Ignition lead

Related codes

F.29

Your boiler has lost its flame during operation and failed to restart, usually because the gas supply has been briefly interrupted or the ignition system cannot spark properly.

High Engineer only £100-250

Parts commonly replaced

  • Ignition lead
  • Spark electrode
  • Gas valve

Related codes

F.32

Your boiler has detected that its internal air fan is spinning much faster than it should be when trying to start up.

High Engineer only £150-350

Parts commonly replaced

  • Fan assembly
  • Wiring harness
  • Printed circuit board (PCB)

Related codes

F.60

Your boiler has detected an internal electrical safety fault within the gas control system, so it has safely shut down to prevent any hazard.

Emergency Engineer only £150-350

Parts commonly replaced

  • Gas valve assembly
  • Wiring harness
  • Main PCB (Electronic control board)

Related codes

F.61

Your boiler has detected an electrical fault with the valve that controls the gas supply, meaning it has safely shut down to prevent any risk.

Emergency Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Wiring harness / cable loom
  • Main printed circuit board (PCB)

Related codes

F.62

Your boiler has detected an issue with the internal gas valve failing to shut off correctly when required, which poses a safety risk.

Emergency Engineer only £150-350

Parts commonly replaced

  • Gas valve
  • Main circuit board

Related codes

F.63

Your boiler has suffered an internal computer memory error, meaning the main control board has failed and cannot save its settings.

High Engineer only £200-400

Parts commonly replaced

  • Main PCB

Related codes

F.64

Your boiler has detected an issue with its internal temperature sensors or main electronics, meaning it cannot accurately measure how hot the water is.

High Engineer only £150-300

Parts commonly replaced

  • Flow/Return NTC Temperature Sensor
  • Main Printed Circuit Board (PCB)

Related codes

F.65

Your boiler has temporarily stopped working because the main computer board inside has become too hot.

High Engineer only £150-350

Parts commonly replaced

  • Main PCB
  • Wiring harness

Related codes

Showing 21–27 of 27
F.70

Your boiler has lost its identity programming after a replacement part was fitted incorrectly, meaning it doesn't know how to run properly.

High Engineer only £90-180

Parts commonly replaced

  • Main Circuit Board (PCB)

Related codes

F.71

Your boiler has temporarily stopped working because the sensor that measures the water temperature inside has stopped updating correctly.

High Engineer only £120-£220

Parts commonly replaced

  • Flow NTC sensor
  • Wiring harness

Related codes

F.72

Your boiler is temporarily locked out because it has detected a disagreement or fault between the temperature sensors on its main pipes.

Medium Engineer only £120-200

Parts commonly replaced

  • Flow sensor
  • Return sensor
  • Sensor wiring harness

Related codes

F.73

Your boiler has lost its reading on the water pressure inside the system because the sensor or its wiring is faulty.

High Engineer only £120-220

Parts commonly replaced

  • Water pressure sensor
  • Pressure sensor wiring harness

Related codes

F.74

Your boiler has detected an electrical fault with its internal water pressure sensor, meaning it cannot correctly read the pressure inside the system.

Medium Engineer only £100-£220

Parts commonly replaced

  • Water pressure sensor
  • Wiring harness

Related codes

F.75

Your boiler has noticed that the water pressure doesn't jump up when the internal pump turns on, which usually means there is either not enough water in the system or the pressure sensor is struggling to read it correctly.

High Engineer only £120-£250

Parts commonly replaced

  • Water pressure sensor
  • Central heating pump

Related codes

F.76

Your boiler has detected dangerously high temperatures inside its main heating unit, triggering an emergency safety lock-out.

Emergency Engineer only £250-£600

Parts commonly replaced

  • Primary heat exchanger
  • Thermal fuse
  • Wiring harness

Related codes

92 operating states & engineer diagnostics

Not faults — these are normal operating states. Tap to expand.

d.00 Diagnostic This code is not actually an error, but simply a normal status message showing the current heating power setting configured for your boiler. d.01 Diagnostic Your boiler is displaying an informational status code showing how long the internal water pump continues to run after your heating turns off to safely dissipate leftover heat. d.02 Diagnostic Your boiler is taking a mandatory temporary rest to prevent it from turning on and off too rapidly, which is a normal protective feature rather than a fault. d.03 Diagnostic Your boiler is displaying a diagnostic reading showing the current temperature of the hot water flowing through the system. d.05 Diagnostic Your boiler is displaying its current target heating temperature rather than an actual error, which is a normal status message to let you know what temperature it is aiming for. d.06 Diagnostic Your boiler is simply displaying the current temperature setting for your hot water. d.07 Diagnostic Your boiler is displaying an informational code related to its hot water pre-heating feature, which typically does not affect this specific model. d.08 Diagnostic Your boiler is simply showing an operational status message to let you know it has received a signal from your room thermostat or programmer to turn on the heating. d.09 Diagnostic Your boiler is having trouble communicating with your external thermostat or heating controller, meaning it might not know when to turn on. d.10 Diagnostic Your boiler is displaying a status message indicating that the internal water pump used for heating is currently active. d.11 Diagnostic Your boiler is displaying a status message indicating that an external pump used to circulate heating around your home is currently running. d.17 Diagnostic Your boiler is temporarily registering that the pipes carrying hot water for your heating and hot water systems might be set up the wrong way around. d.18 Diagnostic Your boiler is displaying an informational code about how the water pump is operating, which typically does not indicate a breakdown. d.19 Diagnostic Your boiler is displaying an informational status code relating to the speed or operating mode of the internal heating pump, rather than a critical breakdown. d.22 Diagnostic Your boiler has simply registered that there is a call for hot water from a tap or shower. d.23 Diagnostic Your boiler is simply indicating whether it is set to provide central heating or just hot water based on the seasonal setting. d.25 Diagnostic Your boiler's built-in timer is currently sending a signal to heat your hot water, which is a normal operational status message rather than an actual fault. d.26 Diagnostic Your boiler has detected an internal communication or relay issue between the main control board and the internal switching components. d.30 Diagnostic Your boiler is detecting an issue with the electrical signals controlling the internal gas supply valves, which safely prevents the boiler from operating. d.33 Diagnostic Your boiler is checking the speed of the internal fan that safely pushes waste gases outside, but it is not hitting the required target. d.34 Diagnostic Your boiler is having trouble monitoring the internal exhaust fan, which is stopping it from operating safely. d.35 Diagnostic Your boiler is displaying an informational code intended for combination boilers, which usually does not affect this heating-only model. d.36 Diagnostic Your boiler is having trouble accurately reading the temperature of the water it is heating, so it has temporarily paused to keep things safe. d.40 Diagnostic Your boiler is displaying an informational reading showing the current temperature of the water leaving the boiler to heat your home. d.41 Diagnostic Your boiler is detecting an issue with the temperature of the water returning from your heating system, which usually points to a faulty sensor or poor water flow. d.44 Diagnostic Your boiler is temporarily monitoring the flame sensor, but this code is usually an informational diagnostic status rather than a critical system failure. d.47 Diagnostic Your boiler has lost the signal from the weather sensor outside, but your heating and hot water will continue to work normally using standard indoor settings. d.50 Diagnostic Your boiler is displaying a diagnostic setting showing the adjusted operating speed for its lowest flame level. d.51 Diagnostic Your boiler is displaying a diagnostic status code rather than a fault, indicating an internal adjustment setting for the fan speed. d.60 Diagnostic Your boiler has recorded several instances where it got too hot and temporarily shut itself down to prevent damage. d.61 Diagnostic Your boiler has recorded multiple recent safety lockouts, meaning it has repeatedly shut itself down to prevent a potential hazard. d.64 Diagnostic Your boiler is measuring the average time it takes for the burner to light successfully. d.65 Diagnostic Your boiler is taking longer than usual to light during start-up, which has caused it to temporarily lock out for safety. d.67 Diagnostic Your boiler is temporarily pausing before firing up again to prevent it from wearing out too quickly. d.68 Diagnostic Your boiler is simply recording a diagnostic status message to track how reliably the burner starts up on the first try. d.69 Diagnostic Your boiler is noting that it successfully lit on its second try rather than the first, which is typically just an informational status message rather than a breakdown. d.70 Diagnostic Your boiler is checking or adjusting the internal valve that directs hot water between your radiators and your taps. d.71 Diagnostic Your boiler is displaying an informational setting showing the maximum temperature limit currently allowed for your heating system. d.72 Diagnostic Your boiler is checking the time it takes for water to return from heating up your hot water tank, which is a normal informational status display rather than a dangerous fault. d.73 Diagnostic Your boiler is displaying an internal configuration code that applies to a different model type, so it is just a harmless system notification rather than an active fault. d.75 Diagnostic Your boiler has timed out while trying to heat your hot water storage cylinder, suggesting it is taking too long to reach the desired temperature. d.76 Diagnostic Your boiler is displaying a configuration code that indicates the internal system settings need to be updated or matched to your specific property setup. d.77 Diagnostic Your boiler is adjusting the heating power limit specifically used to warm up your hot water storage cylinder, which is normally an informational status message rather than a breakdown. d.78 Diagnostic Your boiler has detected that the water temperature inside your hot water cylinder is reaching or exceeding its safety limit while heating up. d.80 Diagnostic This is simply an informational message showing the total number of hours your boiler has been actively heating your home. d.81 Diagnostic Your boiler is simply displaying an informational status message showing the total number of hours it has spent heating water, rather than indicating an actual fault. d.82 Diagnostic Your boiler is temporarily pausing its heating cycle to prevent the system from getting too hot or cycling on and off too frequently. d.83 Diagnostic Your boiler is temporarily pausing or adjusting how it heats your hot water to prevent the system from getting too hot too quickly. d.84 Diagnostic Your boiler is simply reminding you that it is time for its regular annual service and safety check. d.90 Diagnostic Your boiler is simply displaying a normal status message to show it is communicating with your digital room thermostat or controller. d.91 Diagnostic Your boiler is simply checking for an optional radio-controlled outdoor weather sensor signal to automatically adjust the time or temperature, which does not affect your heating or hot water. d.93 Diagnostic Your boiler has lost its specific configuration settings, usually following a circuit board replacement or memory reset. d.97 Diagnostic Your boiler has entered a hidden technical settings menu rather than suffering from a dangerous hardware failure. P.1 Diagnostic Your boiler is currently running a special testing program at full power, which is usually activated by an engineer during a service or setup. P.2 Diagnostic Your boiler is currently running a special internal testing mode using a very low gas level, which usually happens during a setup or diagnostic check. P.3 Diagnostic Your boiler has detected that the water temperature is rising far too quickly, which usually points to a temporary blockage or poor water flow through the system. P.4 Diagnostic Your boiler is temporarily locked out because the water pressure inside the system has dropped too low. P.5 Diagnostic Your boiler is currently running a special internal safety test to check that its temperature limits are working correctly, rather than suffering from a dangerous breakdown. P.6 Diagnostic Your boiler has temporarily stopped because it detected a sudden and unusual rise in internal temperature. S.00 Status Your boiler is currently on standby and is not receiving a signal from your thermostat or timer to provide heating or hot water. S.01 Status Your boiler's internal extraction fan is currently running normally as part of its standard startup cycle. S.02 Status Your boiler is simply running its internal water pump to circulate water through the system, which is a normal part of its operation. S.03 Status Your boiler is currently attempting to light the gas burner and start up normally. S.04 Status Your boiler is operating normally and has successfully ignited the burner to provide heating or hot water. S.05 Status Your boiler is simply preparing to start up by running its fan and water pump. S.06 Status Your boiler is safely running its fan for a short period after heating finishes to clear out any leftover hot air, which is a normal part of its shutdown process. S.07 Status Your boiler's water pump is running for a short period after the heating or hot water turns off to safely clear away leftover heat. S.08 Status Your boiler is taking a temporary, normal rest to avoid turning on and off too frequently. S.10 Status Your boiler has received a signal to provide hot water and is operating normally. S.11 Status Your boiler's internal extraction fan is currently running as a normal part of the start-up sequence, which usually clears on its own once the system proceeds. S.13 Status Your boiler is currently trying to light the flame, which is a normal part of its startup process and usually clears on its own. S.14 Status Your boiler is operating normally and has successfully ignited the burner to provide heating or hot water. S.15 Status Your boiler is simply running its fan and water pump as part of its normal operation or safety check, so you do not need to worry. S.16 Status Your boiler is temporarily running its internal exhaust fan to safely cool down the system after a heating cycle finishes. S.17 Status Your boiler is temporarily running its water pump to safely cool down after finishing a heating or hot water cycle. S.20 Status Your boiler has registered a demand to provide instant hot water pre-heating. S.21 Status Your boiler's internal extraction fan is currently running as part of its normal safety and operation cycle. S.22 Status Your boiler's water circulation pump is currently running to prepare your heating system to fire up. S.23 Status Your boiler is simply running through its normal startup routine to try and light the burner. S.24 Status Your boiler is simply showing that the burner has successfully lit and is currently working to heat your home. S.25 Status Your boiler is currently running its fan and water pump as part of its normal operation or safety check, rather than showing a critical fault. S.26 Status Your boiler's fan is currently running to safely clear out any remaining hot gases after the heating has finished. S.27 Status Your boiler is simply running its pump to safely move leftover heat away from the heat exchanger after finishing a cycle, which is a normal part of its shutdown process. S.28 Status Your boiler is temporarily pausing between heating cycles to prevent it from turning on and off too frequently, which is completely normal operation. S.30 Status Your boiler is currently paused because your room thermostat, programmer, or smart controller is not asking it to provide heating. S.31 Status Your boiler is currently pausing its central heating because the heating temperature control has been turned all the way down or switched off. S.32 Status Your boiler has temporarily paused to protect itself because it detected unusual activity with the internal fan. S.34 Status Your boiler has temporarily switched on its internal frost protection mode to prevent the water inside the pipes from freezing. S.36 Status Your boiler is currently on standby because your thermostat or timer is not asking it to provide heating. S.53 Status Your boiler has temporarily locked itself because the water inside is not circulating properly and getting too hot in one part of the system. S.54 Status Your boiler has temporarily paused heating because it sensed a rapid rise in temperature caused by a shortage of water inside the system. S.76 Status Your boiler has temporarily locked itself because the water pressure inside the system is too low.